Unknown

Dataset Information

0

Circulating cytokines and small molecules follow distinct expression patterns in acute myeloid leukaemia.


ABSTRACT: BACKGROUND:Although aberrant expression of cytokines and small molecules (analytes) is well documented in acute myeloid leukaemia (AML), their co-expression patterns are not yet identified. In addition, plasma baselines for some analytes that are biomarkers for other cancers have not been previously reported in AML. METHODS:We used multiplex array technology to simultaneously detect and quantify 32 plasma analyte (22 reported analytes and 10 novel analytes) levels in 38 patients. RESULTS:In our study, 16 analytes are found to be significantly deregulated (13 higher, 3 lower, Mann-Whitney U-test, P-value <0.005), where 5 of them have never been reported before in AML. We predicted a seven-analyte-containing multiplex panel for diagnosis of AML and, among them, MIF could be a possible therapeutic target. In addition, we observed that circulating analytes show five co-expression signatures. CONCLUSIONS:Circulating analyte expression in AML significantly differs from normal, and follow distinct expression patterns.

SUBMITTER: Islam M 

PROVIDER: S-EPMC5680464 | biostudies-other | 2017 Nov

REPOSITORIES: biostudies-other

altmetric image

Publications

Circulating cytokines and small molecules follow distinct expression patterns in acute myeloid leukaemia.

Islam Mirazul M   Mohamed Elsa Haniffah EH   Esa Ezalia E   Kamaluddin Nor Rizan NR   Zain Shamsul Mohd SM   Yusoff Yuslina Mat YM   Assenov Yassen Y   Mohamed Zahurin Z   Zakaria Zubaidah Z  

British journal of cancer 20170912 10


<h4>Background</h4>Although aberrant expression of cytokines and small molecules (analytes) is well documented in acute myeloid leukaemia (AML), their co-expression patterns are not yet identified. In addition, plasma baselines for some analytes that are biomarkers for other cancers have not been previously reported in AML.<h4>Methods</h4>We used multiplex array technology to simultaneously detect and quantify 32 plasma analyte (22 reported analytes and 10 novel analytes) levels in 38 patients.<  ...[more]

Similar Datasets

| S-EPMC7105340 | biostudies-literature
| S-EPMC3468705 | biostudies-literature
| S-EPMC2373886 | biostudies-literature
2019-12-20 | MSV000084730 | MassIVE
| S-EPMC5525060 | biostudies-other
| S-EPMC6912424 | biostudies-literature
| S-EPMC5674101 | biostudies-literature