EFFECT OF DIFFERENT POOLED QC SAMPLES ON DATA QUALITY DURING AN INTER-BATCH EXPERIMENT IN UNTARGETED UHPLC-HRMS ANALYSIS ON TWO DIFFERENT MS PLATFORMS


ABSTRACT: Quality control (QC) samples are commonly used in metabolomics approaches for three main reasons: (i) the initial conditioning of the column; (ii) the correction of analytical drift especially between batches; and (iii) the evaluation of measurement precision. In practice there are several ways to prepare and conserve QC samples. The most common in untargeted metabolomics is to pool samples after or before extraction, in order to obtain pooled QC samples accounting respectively for analytical variance or for both analytical and sample preparation variances. In this study, focusing on untargeted analysis of tea (Camellia sinensis) leaves, we compared three ways of preparing pooled QC samples (two usual and one unusual QC sample preparations) and their efficiency to improve data quality in terms of inter-batch correction, measurement precision, and VIP candidates selection on datasets obtained using two mass spectrometry (MS) technologies (Orbitrap and time of flight (QToF)). We also investigated the effect of data processing modalities, based on the different QC preparations, on data loss and on the global structure of the datasets. Generally, our results show that usual QC sample preparation leads to comparable datasets quality in terms of precision and dispersion in both MS instruments. They also show that QC preparation is crucial for VIP selection, in fact, up to 54% of biomarkers candidates are specific of the QC preparation type used for data processing.

INSTRUMENT(S): Liquid Chromatography MS - negative - reverse phase, Liquid Chromatography MS - positive - reverse phase

PROVIDER: MTBLS10568 | MetaboLights | 2026-02-04

REPOSITORIES: MetaboLights

Dataset's files

Source:
Action DRS
neg20230511_Bk_extr1.mzML Mzml
neg20230511_Bk_extr2.mzML Mzml
neg20230511_Bk_extr3.mzML Mzml
neg20230511_Bk_extr4.mzML Mzml
neg20230511_Bk_extr5.mzML Mzml
Items per page:
1 - 5 of 618
altmetric image

Publications

Effect of different pooled qc samples on data quality during an inter-batch experiment in untargeted UHPLC-HRMS analysis on two different MS platforms.

Ramos Mélina M   Camel Valérie V   Le Roux Even E   Farah Soha S   Cladiere Mathieu M  

Analytical and bioanalytical chemistry 20241118 2


Quality control (QC) samples are commonly used in metabolomics approaches for three main reasons: (i) the initial conditioning of the column; (ii) the correction of analytical drift especially between batches; and (iii) the evaluation of measurement precision. In practice, there are several ways to prepare and conserve QC samples. The most common in untargeted metabolomics is to pool samples after or before extraction, in order to obtain pooled QC samples accounting, respectively, for analytical  ...[more]

Similar Datasets

2018-08-31 | MTBLS694 | MetaboLights
2018-10-21 | GSE109351 | GEO
2023-09-29 | GSE244325 | GEO
2023-05-24 | PXD040497 | Pride
2022-03-01 | MTBLS719 | MetaboLights
| PRJNA1057152 | ENA
2019-06-13 | MTBLS623 | MetaboLights
2020-06-09 | PXD018874 | Pride
2023-06-22 | MSV000092245 | MassIVE
2026-01-20 | MTBLS13731 | MetaboLights