Metabolomics

Dataset Information

0

An LC-MS untargeted metabolomic comparison between three blood microsampling devices, whole blood, and plasma


ABSTRACT:

Blood microsampling (BµS) devices collect less than 100 µL of blood, offering a less invasive and more cost-effective alternative to venipuncture. However, its metabolomic comparability to conventional samples remains unclear, and standardized BµS metabolomic workflows are lacking. This study compared BµS extraction methods and assessed the metabolite coverage of three BµS devices (Mitra®, Capitainer®, and Whatman™ 903) as an alternative to conventional samples (plasma and whole blood) for human biomonitoring. Venous blood from 10 adults (5 males, 5 females) was sampled onto the three devices. First, three extraction techniques (ultrasound, shaker, and homogenizer) were evaluated at three blood concentrations (1.5%, 5.5%, and 11%). The optimized method was then used to compare the metabolite profiles between BµS devices, whole blood, and plasma. Reverse-phase and hydrophilic-interaction chromatography, in positive and negative ionization modes, were combined for Liquid Chromatography–Mass Spectrometry (LC-MS) analysis. All extraction techniques and concentrations proved suitable for BµS untargeted metabolomics. Combining different analytical modes and fragmentation ranges proved useful for maximizing metabolite coverage. BµS-derived metabolite profiles aligned more closely with whole blood than plasma. Some metabolites were more characteristic of a sample type, whereas others were common across sample types. All sample types enabled sex-based differentiation, with metabolites such as testosterone sulfate and hydroxyisovaleric acid driving the separation. These findings enhance our understanding of BµS metabolite coverage and highlight its potential in human biomonitoring. The choice of device depends on the application and the metabolites of interest, offering flexibility for clinical use and research. 

INSTRUMENT(S): Liquid Chromatography MS - negative - reverse phase, Liquid Chromatography MS - positive - hilic, Liquid Chromatography MS - - reverse phase, Liquid Chromatography MS - negative - hilic

PROVIDER: MTBLS10740 | MetaboLights | 2026-06-01

REPOSITORIES: MetaboLights

altmetric image

Publications

An LC-MS untargeted metabolomic comparison between three blood microsampling devices, whole blood, and plasma.

Avella Dennisse D   Turunen Soile S   Avgerinou Glykeria G   Petridou Anatoli A   Mougios Vassilis V   Zarei Iman I   Auriola Seppo S   Hanhineva Kati K   Kärkkäinen Olli O  

Metabolomics : Official journal of the Metabolomic Society 20260529 3


<h4>Introduction</h4>Blood microsampling (BµS) devices collect less than 100 µL of blood, offering a less invasive and more cost-effective alternative to venipuncture. However, its metabolomic comparability to conventional samples remains unclear, and standardized BµS metabolomic workflows are lacking.<h4>Objectives</h4>This study evaluated the impact of using three BµS devices (Mitra<sup>®</sup>, Capitainer<sup>®</sup>, and Whatman<sup>™</sup> 903) on the metabolomic interpretation of human bio  ...[more]

Similar Datasets

2026-01-13 | MTBLS13090 | MetaboLights
| MSV000099001 | MassIVE
2023-01-17 | PXD038750 | Pride
2019-09-20 | GSE103889 | GEO
2023-05-03 | GSE226930 | GEO
2025-09-30 | MTBLS10722 | MetaboLights
2025-06-04 | PXD056469 | Pride
2018-10-16 | PXD010171 | Pride
2014-01-01 | E-GEOD-43454 | biostudies-arrayexpress
2024-05-31 | PXD048358 | Pride