Metabolomics

Dataset Information

Metabolomic data of Vibrio parahaemolyticus obtained by DMSP


ABSTRACT:

This experiment focused on solid samples of Vibrio parahaemolyticus. 50 +/- 5 mg of the samples were accurately weighed and placed in 2 mL centrifuge tubes. 6 mm grinding beads and 400 uL of extraction solution (methanol:water = 4:1, v:v) containing four internal standards (L-2-chloropropionylglycine at 0.02 mg/mL, etc.) were added. The samples were then ground for 6 minutes using a frozen tissue grinder (-10 °C, 50 Hz), followed by 30 minutes of low-temperature ultrasonic extraction (5 °C, 40 kHz). The mixture was left to stand at -20 °C for 30 minutes, then centrifuged at 13000 g for 15 minutes at 4 °C. The supernatant was collected and analyzed on the instrument. Equal volumes of the supernatants of each sample were mixed to prepare QC samples. LC-MS detection was performed using the Thermo Scientific Vanquish UHPLC tandem Exploris 240 mass spectrometry system. The chromatographic column was ACQUITY UPLC HSS T3 (100 mm x 2.1 mm i.d., 1.8 um). The mobile phase A was 95% water + 5% acetonitrile (containing 0.1% formic acid), and B was 47.5% acetonitrile + 47.5% isopropanol + 5% water (containing 0.1% formic acid). The injection volume was 3 uL, the column temperature was 40 °C, the flow rate was 0.40 mL/min, and the gradient elution was as follows: 0-1.5 min B 0% to 5%, 1.5-2 min 5% to 10%, 2-4.5 min 10% to 30%, 4.5-5 min 30% to 100%, 5-6.3 min maintained at 100%, 6.3-6.4 min 100% to 0%, 6.4-8 min maintained at 0%. The mass spectrometry used ESI positive and negative ion scanning modes, with a scanning range of m/z 70-1050. The capillary temperature was 350 °C, the spray voltage was 3400 V/-3000 V in positive/negative mode, the S-Lens was 60, the normalization collision energy was 20/40/60%, and the Full MS resolution was 60000, the MS2 resolution was 15000. During the analysis, a QC sample was inserted every 5-15 samples to monitor stability. The raw data were filtered, identified, integrated, and corrected for retention time and peak alignment using Progenesis QI v3.0, and the MS and MS/MS information was matched with public databases such as HMDB and METLIN (MS mass error < 10 ppm) to complete metabolite identification. At the same time, the stability of the experimental process was evaluated using the z-score of the internal standard (2 times the standard deviation range).

INSTRUMENT(S): Liquid Chromatography MS - negative - reverse-phase, Liquid Chromatography MS - positive - reverse-phase

PROVIDER: MTBLS16539 | MetaboLights | 2026-11-22

REPOSITORIES: MetaboLights