Proteomics

Dataset Information

0

ITRAQ LLC-PK1 CnI - Sum of peak intensities outperforms peak area integration in iTRAQ protein expression measurement by LC-MS/MS using a TripleTOF 5600+ platform


ABSTRACT: In the field of quantitative proteomics, the Isobaric Tags for Relative & Absolute Quanti-tation (iTRAQ) technology has demonstrated efficacy for proteome monitoring despite its lack of a consensus for data handling. In this study, after peptide and protein identification, we com-pared the widespread quantitation method based on the calculation of MS/MS reporter ion peaks areas ratios (Protein Pilot) to the alternative method based on the calculation of ratios of the sum of peak intensities (jTRAQx (Quant)) and we processed output data with the in-house Customi-zable iTRAQ Ratios Calculator (CiR-C) algorithm. Quantitation based on peak area ratios dis-played no significant linear correlation with Western blot quantitation. On the contrary, quantita-tion based on the sum of peak intensities displayed a significant linear association with Western blot quantitation (non-zero slope; Pearson correlation coefficient test, r = 0.2962, p = 0.0099 **) with an average bias of 0.08747 ± 0.5004 and 95% Limits of Agreement from - 0.8932 to 1.068. We proposed the Mascot-jTRAQx-CiR-C strategy as a simple yet powerful data processing ad-junct to the iTRAQ technology

INSTRUMENT(S): TripleTOF 5600

ORGANISM(S): Sus Scrofa Domesticus (domestic Pig)

TISSUE(S): Epithelial Cell, Kidney

SUBMITTER: Bastien Burat  

LAB HEAD: Marie Essig

PROVIDER: PXD007891 | Pride | 2019-08-19

REPOSITORIES: Pride

altmetric image

Publications

Sum of peak intensities outperforms peak area integration in iTRAQ protein expression measurement by LC-MS/MS using a TripleTOF 5600+ platform.

Burat Bastien B   Gonzalez Julien J   Sauvage François-Ludovic FL   Aouad Hassan H   Arnion Hélène H   Pinault Emilie E   Marquet Pierre P   Essig Marie M  

Bioscience reports 20190607 6


In the field of quantitative proteomics, the Isobaric Tags for Relative and Absolute Quantitation (iTRAQ) technology has demonstrated efficacy for proteome monitoring despite its lack of a consensus for data handling. In the present study, after peptide and protein identification, we compared the widespread quantitation method based on the calculation of MS/MS reporter ion peaks areas ratios (ProteinPilot) to the alternative method based on the calculation of ratios of the sum of peak intensitie  ...[more]

Similar Datasets

2019-03-04 | PXD012207 | Pride
2010-06-09 | E-GEOD-3508 | biostudies-arrayexpress
2005-10-28 | GSE3508 | GEO
2005-01-01 | E-MNIA-67 | biostudies-arrayexpress
2021-05-06 | PXD021875 | Pride
2010-07-01 | E-GEOD-4495 | biostudies-arrayexpress
2020-03-24 | PXD016192 | Pride
2010-11-09 | E-GEOD-24436 | biostudies-arrayexpress
2015-06-08 | PXD002142 | Pride
2015-01-30 | PXD001574 | Pride