Unknown

Dataset Information

0

Quinoline-Malononitrile-Based Aggregation-Induced Emission Probe for Monoamine Oxidase Detection in Living Cells.


ABSTRACT: A quinoline-malononitrile (QM)-based aggregation-induced emission probe was developed to detect MAOs in cells through an enzymatic reaction followed by β-elimination. After being incubated at 37 °C, QM-NH2 responded to the MAO enzymes with great specificity and within just 5 min. This 5 min responsive mechanism was fast, with the limit of detection (LOD) at 5.49 and 4.76 µg mL-1 for MAO-A and MAO-B, respectively. Moreover, QM-NH2 displayed high enzyme specificity even in the presence of high concentrations of biological interferences, such as oxidizing and reducing agents, biothiols, amino acids, and glucose. Furthermore, QM-NH2 demonstrated biocompatibility as the cells retained more than 70% viability when exposed to QM-NH2 at concentrations of up to 20 µM. As a result, QM-NH2 was used to detect MAO-A and MAO-B in SH-SY5Y and HepG2 cells, respectively. After 1h incubation with QM-NH2, the cells exhibited enhanced fluorescence by about 20-fold. Moreover, the signal from cells was reduced when MAO inhibitors were applied prior to incubating with QM-NH2. Therefore, our research recommends using a QM probe as a generic method for producing recognition moieties for fluorogenic enzyme probes.

SUBMITTER: Duangkamol C 

PROVIDER: S-EPMC10054884 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quinoline-Malononitrile-Based Aggregation-Induced Emission Probe for Monoamine Oxidase Detection in Living Cells.

Duangkamol Chuthamat C   Wangngae Sirilak S   Wet-Osot Sirawit S   Khaikate Onnicha O   Chansaenpak Kantapat K   Lai Rung-Yi RY   Kamkaew Anyanee A  

Molecules (Basel, Switzerland) 20230315 6


A quinoline-malononitrile (QM)-based aggregation-induced emission probe was developed to detect MAOs in cells through an enzymatic reaction followed by β-elimination. After being incubated at 37 °C, <b>QM-NH<sub>2</sub></b> responded to the MAO enzymes with great specificity and within just 5 min. This 5 min responsive mechanism was fast, with the limit of detection (LOD) at 5.49 and 4.76 µg mL<sup>-1</sup> for MAO-A and MAO-B, respectively. Moreover, <b>QM-NH<sub>2</sub></b> displayed high enzy  ...[more]

Similar Datasets

| S-EPMC10296659 | biostudies-literature
| S-EPMC4976310 | biostudies-literature
| S-EPMC6217697 | biostudies-literature
| S-EPMC8495881 | biostudies-literature
| S-EPMC9086254 | biostudies-literature
| S-EPMC11756592 | biostudies-literature
| S-EPMC11314084 | biostudies-literature
| S-EPMC6644794 | biostudies-literature
| S-EPMC9502896 | biostudies-literature
| S-EPMC11234465 | biostudies-literature