Unknown

Dataset Information

0

Electrochemical lateral-flow device for rapid COVID-19 antigen-diagnostic testing.


ABSTRACT: Antigen test kits (ATK) are extensively utilized for screening and diagnosing COVID-19 because they are easy to operate. However, ATKs exhibit poor sensitivity and cannot detect low concentrations of SARS-CoV-2. Herein, we present a new, highly sensitive, and selective device obtained by combining the principle of ATKs with electrochemical detection for COVID-19 diagnosis, which can be quantitatively assessed using a smartphone. An electrochemical test strip (E-test strip) was constructed by attaching a screen-printed electrode inside a lateral-flow device to exploit the remarkable binding affinity of SARS-CoV-2 antigen to ACE2. The ferrocene carboxylic acid attached to SARS-CoV-2 antibody acts as an electroactive species when it binds to SARS-CoV-2 antigen in the sample before it flows continuously to the ACE2-immobilization region on the electrode. Electrochemical-assay signal intensity on smartphones increased proportionally to the concentration of SARS-CoV-2 antigen (LOD = 2.98 pg/mL, under 12 min). Additionally, the application of the single-step E-test strip for COVID-19 screening was demonstrated using nasopharyngeal samples, and the results were consistent with those obtained using the gold standard (RT-PCR). Therefore, the sensor demonstrated excellent performance in assessing and screening COVID-19, and it can be used professionally to accurately verify diagnostic data while remaining rapid, simple, and inexpensive.

SUBMITTER: Deenin W 

PROVIDER: S-EPMC10077809 | biostudies-literature | 2023 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrochemical lateral-flow device for rapid COVID-19 antigen-diagnostic testing.

Deenin Wanwisa W   Yakoh Abdulhadee A   Pimpitak Umaporn U   Pasomsub Ekawat E   Rengpipat Sirirat S   Crespo Gastón A GA   Chaiyo Sudkate S  

Bioelectrochemistry (Amsterdam, Netherlands) 20230406


Antigen test kits (ATK) are extensively utilized for screening and diagnosing COVID-19 because they are easy to operate. However, ATKs exhibit poor sensitivity and cannot detect low concentrations of SARS-CoV-2. Herein, we present a new, highly sensitive, and selective device obtained by combining the principle of ATKs with electrochemical detection for COVID-19 diagnosis, which can be quantitatively assessed using a smartphone. An electrochemical test strip (E-test strip) was constructed by att  ...[more]

Similar Datasets

| S-EPMC10858045 | biostudies-literature
| S-EPMC8979030 | biostudies-literature
| S-EPMC8354301 | biostudies-literature
| S-EPMC10903820 | biostudies-literature
| S-EPMC8164528 | biostudies-literature
| S-EPMC7985936 | biostudies-literature
| S-EPMC9178520 | biostudies-literature
| S-EPMC8478097 | biostudies-literature
| S-EPMC8426967 | biostudies-literature