Tensile and Compressive Mechanical Behaviour of Human Blood Clot Analogues.


ABSTRACT: Endovascular thrombectomy procedures are significantly influenced by the mechanical response of thrombi to the multi-axial loading imposed during retrieval. Compression tests are commonly used to determine compressive ex vivo thrombus and clot analogue stiffness. However, there is a shortage of data in tension. This study compares the tensile and compressive response of clot analogues made from the blood of healthy human donors in a range of compositions. Citrated whole blood was collected from six healthy human donors. Contracted and non-contracted fibrin clots, whole blood clots and clots reconstructed with a range of red blood cell (RBC) volumetric concentrations (5-80%) were prepared under static conditions. Both uniaxial tension and unconfined compression tests were performed using custom-built setups. Approximately linear nominal stress-strain profiles were found under tension, while strong strain-stiffening profiles were observed under compression. Low- and high-strain stiffness values were acquired by applying a linear fit to the initial and final 10% of the nominal stress-strain curves. Tensile stiffness values were approximately 15 times higher than low-strain compressive stiffness and 40 times lower than high-strain compressive stiffness values. Tensile stiffness decreased with an increasing RBC volume in the blood mixture. In contrast, high-strain compressive stiffness values increased from 0 to 10%, followed by a decrease from 20 to 80% RBC volumes. Furthermore, inter-donor differences were observed with up to 50% variation in the stiffness of whole blood clot analogues prepared in the same manner between healthy human donors.

SUBMITTER: Cahalane RME 

PROVIDER: S-EPMC10326096 | biostudies-literature | 2023 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Tensile and Compressive Mechanical Behaviour of Human Blood Clot Analogues.

Cahalane Rachel M E RME   de Vries Judith J JJ   de Maat Moniek P M MPM   van Gaalen Kim K   van Beusekom Heleen M HM   van der Lugt Aad A   Fereidoonnezhad Behrooz B   Akyildiz Ali C AC   Gijsen Frank J H FJH  

Annals of biomedical engineering 20230418 8


Endovascular thrombectomy procedures are significantly influenced by the mechanical response of thrombi to the multi-axial loading imposed during retrieval. Compression tests are commonly used to determine compressive ex vivo thrombus and clot analogue stiffness. However, there is a shortage of data in tension. This study compares the tensile and compressive response of clot analogues made from the blood of healthy human donors in a range of compositions. Citrated whole blood was collected from  ...[more]

Similar Datasets

| S-EPMC11247058 | biostudies-literature
| S-EPMC3910320 | biostudies-literature
| S-EPMC8837659 | biostudies-literature
| S-EPMC7183083 | biostudies-literature
| S-EPMC10642823 | biostudies-literature
| S-EPMC4303531 | biostudies-literature
| S-EPMC8184644 | biostudies-literature
| S-EPMC10254679 | biostudies-literature
| S-EPMC8553339 | biostudies-literature
| S-EPMC11779924 | biostudies-literature