Unknown

Dataset Information

0

Ultrafast inactivation of SARS-CoV-2 by 254-nm UV-C irradiation on porous and non-porous media of medical interest using an omnidirectional chamber.


ABSTRACT: Covid-19 has spurred a renewed interest in decontamination techniques for air, objects and surfaces. Beginning in 2020, urgent effort was done to permit the reuse of UV-C for inactivating SARS-CoV-2. However, those studies diverged widely on the dose necessary to reach this goal; until today, the real value of the sensitivity of the virus to a 254-nm illumination is not known precisely. In this study, decontamination was performed in an original UV-C large decontamination chamber (UVCab, ON-LIGHT, France) delivering an omnidirectional irradiation with an average dose of 50 mJ/cm2 in 60 s. Viral inactivation was checked by both cell culture and PCR test. SARS-CoV-2 was inactivated by UV-C light within 3 s on both porous (disposable gown) and non-porous (stainless steel and apron) surfaces. For the porous surface, an irradiation of 5 min was needed to achieve a completely negative PCR signal. The Z value estimating the sensitivity of SARS-CoV-2 to UV-C in the experimental conditions of our cabinet was shown to be > 0.5820 m2/J. These results illustrate the ability of this apparatus to inactivate rapidly and definitively high loads of SARS-CoV-2 deposited on porous or non-porous supports and opens new perspectives on material decontamination using UV-C.

SUBMITTER: Maubert B 

PROVIDER: S-EPMC10403608 | biostudies-literature | 2023 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrafast inactivation of SARS-CoV-2 by 254-nm UV-C irradiation on porous and non-porous media of medical interest using an omnidirectional chamber.

Maubert Bertrand B   Theillière Camille C   Jany Prescillia P   Bourlet Thomas T   Deschamps Jérôme J   Pozzetto Bruno B   Singh Fateh F   Gadea Emilie E  

Scientific reports 20230804 1


Covid-19 has spurred a renewed interest in decontamination techniques for air, objects and surfaces. Beginning in 2020, urgent effort was done to permit the reuse of UV-C for inactivating SARS-CoV-2. However, those studies diverged widely on the dose necessary to reach this goal; until today, the real value of the sensitivity of the virus to a 254-nm illumination is not known precisely. In this study, decontamination was performed in an original UV-C large decontamination chamber (UVCab, ON-LIGH  ...[more]

Similar Datasets

| S-EPMC9538331 | biostudies-literature
| S-EPMC8532508 | biostudies-literature
| S-EPMC9347497 | biostudies-literature
| S-EPMC9281457 | biostudies-literature
| S-EPMC9308144 | biostudies-literature
| S-EPMC8857861 | biostudies-literature
| S-EPMC9284107 | biostudies-literature
| S-EPMC10241504 | biostudies-literature
| S-EPMC9617911 | biostudies-literature
| S-EPMC8420338 | biostudies-literature