Unknown

Dataset Information

0

Development of a Pure Certified Reference Material of D-Mannitol.


ABSTRACT: A new certified reference material (CRM) of D-mannitol (GBW(E) 100681) has been developed in this study. We describe the preparation, structure determination, characterization, homogeneity study, stability study, as well as uncertainty estimation. The main component was 99.91% ± 0.01%. The moisture content of the candidate CRM was 0.036% ± 0.002%, as measured by Karl Fischer titration. The nonvolatile and volatile impurities in the candidate CRM were all much less than 0.01%, which was determined by the ICP-MS and headspace GC-FID methods, respectively. The purity of the D-mannitol CRM was 99.9% ± 1.1% (k = 2), as measured by the two independent approaches involving the mass balance method (MB) and quantitative nuclear magnetic resonance technique (qNMR). The D-mannitol CRM was stable during the monitoring period for each temperature. It is stable for up to 48 months at room temperature and 28 days at 50 °C. The uncertainty was evaluated by combining the contributions from characterization, homogeneity, and stability. The developed D-mannitol CRM would effectively support method validation and proficiency testing, as well as effectively guarantee the accuracy, reliability, and comparability of results.

SUBMITTER: Chen W 

PROVIDER: S-EPMC10574156 | biostudies-literature | 2023 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development of a Pure Certified Reference Material of D-Mannitol.

Chen Weizhu W   Zhang Yiping Y   Chen Hui H   Jin Wenhui W   Chen Xiaoying X   Huang Xiaoyan X   Xie Yanrou Y   Fang Hua H   Hong Zhuan Z  

Molecules (Basel, Switzerland) 20230925 19


A new certified reference material (CRM) of D-mannitol (GBW(E) 100681) has been developed in this study. We describe the preparation, structure determination, characterization, homogeneity study, stability study, as well as uncertainty estimation. The main component was 99.91% ± 0.01%. The moisture content of the candidate CRM was 0.036% ± 0.002%, as measured by Karl Fischer titration. The nonvolatile and volatile impurities in the candidate CRM were all much less than 0.01%, which was determine  ...[more]

Similar Datasets

| S-EPMC10488496 | biostudies-literature
| S-EPMC9142433 | biostudies-literature
| S-EPMC9310008 | biostudies-literature
| S-EPMC10474187 | biostudies-literature
| S-EPMC7801322 | biostudies-literature
| S-EPMC11757154 | biostudies-literature
| S-EPMC4917587 | biostudies-literature
| S-EPMC10766801 | biostudies-literature
| S-EPMC7329778 | biostudies-literature
| S-EPMC4320294 | biostudies-literature