Project description:Porphyromonas gingivalis infection is one of the causes of implant failures, which can lead to peri-implantitis. Implant surface roughness is reportedly related strongly to P. gingivalis adhesion, which can lead to peri-implantitis and, later, cell adhesion. Our aim was to evaluate the effects of Er,Cr:YSGG laser on titanium (Ti) disc surfaces and its interaction with bacterial adhesion and fibroblast viability. Ti discs underwent two treatments: autoclaving (control) and erbium, chromium-doped yttrium scandium gallium garnet (Er,Cr:YSGG) laser treatment (test). Ti disc surfaces were examined with scanning electronic microscope (SEM), Energy-dispersive spectrometry (EDX), X-ray photoelectron spectroscopy (XPS). The surface roughness same as wettability were also investigated. Fibroblast viability was assessed with the water-soluble tetrazolium 1 (WST-1) test, and osteoblast differentiation was assessed with the alkaline phosphatase (ALP) assay. Bacterial structure and colony formation were detected with scanning electron microscopy and Gram stain. In comparison to control discs, the test discs showed smoother surfaces, with 0.25-µm decrease in surface roughness (p < 0.05); lower P. gingivalis adhesion (p < 0.01); less P. gingivalis colonization (p < 0.05); and increased fibroblast viability and osteoblast differentiation (p < 0.05). Er,Cr:YSGG laser treatment improved disc surfaces by making them slightly smoother, which reduced P. gingivalis adhesion and increased fibroblast viability and osteoblast differentiation. Er,Cr:YSGG laser treatment can be considered a good option for managing peri-implantitis. Further investigations of laser-assisted therapy are necessary for better guidelines in the treatment of peri-implantitis.
Project description:Calcium ions are used in the development of biomaterials for the promotion of coagulation, bone regeneration, and implant osseointegration. Upon implantation, the time-dependent release of calcium ions from titanium implant surfaces modifies the physicochemical characteristics at the implant-tissue interface and thus, the biological responses. The aim of this study is to examine how the dynamics of protein adsorption on these surfaces change over time. Titanium discs with and without Ca were incubated with human serum for 2 min, 180 min, and 960 min. The layer of proteins attached to the surface was characterised using nLC-MS/MS. The adsorption kinetics was different between materials, revealing an increased adsorption of proteins associated with coagulation and immune responses prior to Ca release. Implant-blood contact experiments confirmed the strong coagulatory effect for Ca surfaces. We employed primary human alveolar osteoblasts and THP-1 monocytes to study the osteogenic and inflammatory responses. In agreement with the proteomic results, Ca-enriched surfaces showed a significant initial inflammation that disappeared once the calcium was released. The distinct protein adsorption/desorption dynamics found in this work demonstrated to be useful to explain the differential biological responses between the titanium and Ca-ion modified implant surfaces.
Project description:BackgroundBiofunctionalization of titanium surfaces can improve host responses, especially considering the time for osteointegration and patient recovery. This prompted us to modify titanium surfaces with alendronate and albumin and to investigate the behavior of osteoblasts on these surfaces.MethodsThe biofunctionalization of titanium surfaces was characterized using classical physicochemical approaches and later used to challenge pre-osteoblast cells up to 24 h. Then their viability and molecular behavior were investigated using mitochondrial dehydrogenase activity and RTq-PCR technologies, respectively. Potential stimulus of extracellular remodeling was also investigated by zymography.ResultsOur data indicates a differential behavior of cells responding to the surfaces, considering the activity of mitochondrial dehydrogenases. Molecularly, the differential expression of genes related with cell adhesion highlighted the importance of Integrin-β1, Fak, and Src. These 3 genes were significantly decreased in response to titanium surfaces modified with alendronate, but this behavior was reverted when alendronate was associated with albumin. Alendronate-modified surfaces promoted a significant increase on ECM remodeling, as well as culminating with greater gene activity related to the osteogenic phenotype (Runx2, Alp, Bsp).ConclusionAltogether, our study found interesting osteogenic behavior of cells in response to alendronate and albumin surfaces, which indicates the need for in vivo analyses to better consider these surfaces before clinical trials within the biomedical field.
Project description:Titanium (Ti) and Ti alloys are used in orthopaedic/spine applications where biological implant fixation, or osseointegration, is required for long-term stability. These implants employ macro-scale features to provide mechanical stability until arthrodesis, features that are too large to influence healing at the cellular level. Micron-scale rough Ti alloy (Ti-6Al-4V) increases osteoblastic differentiation and osteogenic factor production in vitro and increases in vivo bone formation; however, effects of overall topography, including sub-micron scale and nanoscale features, on osteoblast lineage cells are less well appreciated. To address this, Ti6Al4V surfaces with macro/micro/nano-textures were generated using sand blasting and acid etching that had comparable average roughness values but differed in other roughness parameters (total roughness, profile roughness, maximum peak height, maximum valley depth, root-mean-squared roughness, kurtosis, skewness) (#5, #9, and #12). Human mesenchymal stem cells (HMSCs) and normal human osteoblasts (NHOst) were cultured for 7 days on the substrates and then analyzed for alkaline phosphatase activity and osteocalcin content, production of osteogenic local factors, and integrin subunit expression. All three surfaces supported osteoblastic differentiation of HMSCs and further maturation of NHOst cells, but the greatest response was seen on the #9 substrate, which had the lowest skewness and kurtosis. The #9 surface also induced highest expression of α2 and β1 integrin mRNA. HMSCs produced highest levels of ITGAV on #9, suggesting this integrin may play a role for early lineage cells. These results indicate that osteoblast lineage cells are sensitive to specific micro/nanostructures, even when overall macro roughness is comparable and suggest that skewness and kurtosis are important variables.
Project description:During embryogenesis and tissue maintenance and repair in an adult organism, a myriad of stem cells are regulated by their surrounding extracellular matrix (ECM) enriched with tissue/organ-specific nanoscale topographical cues to adopt different fates and functions. Attributed to their capability of self-renewal and differentiation into most types of somatic cells, stem cells also hold tremendous promise for regenerative medicine and drug screening. However, a major challenge remains as to achieve fate control of stem cells in vitro with high specificity and yield. Recent exciting advances in nanotechnology and materials science have enabled versatile, robust, and large-scale stem cell engineering in vitro through developments of synthetic nanotopographical surfaces mimicking topological features of stem cell niches. In addition to generating new insights for stem cell biology and embryonic development, this effort opens up unlimited opportunities for innovations in stem cell-based applications. This review is therefore to provide a summary of recent progress along this research direction, with perspectives focusing on emerging methods for generating nanotopographical surfaces and their applications in stem cell research. Furthermore, we provide a review of classical as well as emerging cellular mechano-sensing and -transduction mechanisms underlying stem cell nanotopography sensitivity and also give some hypotheses in regard to how a multitude of signaling events in cellular mechanotransduction may converge and be integrated into core pathways controlling stem cell fate in response to extracellular nanotopography.
Project description:In this study the gene expression differences between two titanium surfaces produced at Maastricht University were investigated. These two surfaces were: flat titanium-coated polystyrene and a titanium-coated polystyrene surface imprinted with a pattern selected from an earlier screening study (Ti1018). This pattern was selected based on the osteoinductive properties observed. As a positive control cells on the flat surface were treated with dexamethasone.
Project description:ObjectivesMacrophages are among the first cells to interact with the dental implant surface and are critical regulators for controlling the immune response toward biomaterials. Macrophages can polarize between two main phenotypes: proinflammatory M1 macrophages and anti-inflammatory M2 macrophages. This systematic review aims to determine if a differing macrophage inflammatory response exists on hydrophilic sandblasted large grit, acid-etched (SLActive) surfaces compared to sandblasted large grit, acid-etched (SLA) titanium or titanium-zirconium surfaces during in vitro studies. MATERIAL AND METHODS: A systematic search of three electronic databases, Medline, DOSS (Dentistry and Oral Sciences Source), and WoS (Web of Science), was performed. Only in vitro studies were included in this systematic review. The electronic search was supplemented with a search of the references. Genetic expression and production of proinflammatory and anti-inflammatory proteins were assessed. The synthesis of quantitative data was completed by narrative synthesis.ResultsA total of 906 studies were found with the systematic search. Eight studies remained after the application of inclusion and exclusion criteria. Six studies used murine macrophages, while two used human macrophages. Discs were used in six studies, while dental implants were used in the remaining two studies. Genetic expression and cytokine production of proinflammatory cytokines on SLActive surfaces were reduced compared to SLA. Anti-inflammatory genetic expression and cytokine production was increased on SLActive surfaces. The overall quality of the included studies was low to moderate.ConclusionsSLActive surfaces modulate macrophages to reduce proinflammatory and increase anti-inflammatory gene expression and cytokine production compared to SLA surfaces. The in vitro nature of the included studies does not replicate the in vivo healing cascade. Further in vivo studies are required to assess the macrophage response toward SLActive implant surfaces compared to SLA surfaces.
Project description:Droplet nucleation and condensation are ubiquitous phenomena in nature and industry. Over the past century, research has shown dropwise condensation heat transfer on nonwetting surfaces to be an order of magnitude higher than filmwise condensation heat transfer on wetting substrates. However, the necessity for nonwetting to achieve dropwise condensation is unclear. This article reports stable dropwise condensation on a smooth, solid, hydrophilic surface (θa = 38°) having low contact angle hysteresis (<3°). We show that the distribution of nano- to micro- to macroscale droplet sizes (about 100 nm to 1 mm) for coalescing droplets agrees well with the classical distribution on hydrophobic surfaces and elucidate that the wettability-governed dropwise-to-filmwise transition is mediated by the departing droplet Bond number. Our findings demonstrate that achieving stable dropwise condensation is not governed by surface intrinsic wettability, as assumed for the past eight decades, but rather, it is dictated by contact angle hysteresis.
Project description:Dendritic cells (DCs) play a pivotal role in the host response to implanted biomaterials. Osseointegration of titanium (Ti) implant is an immunological and inflammatory-driven process. However, the role of DCs in this complex process is largely unknown. This study aimed to investigate the effect of different Ti surfaces on DC maturation, and evaluate its subsequent potential on osteogenic differentiation of preosteoblasts. Murine bone marrow-derived DCs were seeded on Ti disks with different surface treatments, including pretreatment (PT), sandblasted/acid-etched (SLA) and modified SLA (modSLA) surface. Compared with DCs cultured on PT and SLA surfaces, the cells seeded on modSLA surface demonstrated a more round morphology with lower expression of CD86 and MHC-II, the DC maturation markers. Those cells also secreted high levels of anti-inflammatory cytokine IL-10 and TGF-β. Notably, addition of conditioned medium (CM) from modSLA-induced DCs significantly increased the mRNA expression of Runx2 and ALP as well as ALP activity by murine preosteoblast MC3T3-E1 cells. Our data demonstrated that Ti disks with different surfaces lead to differential DCs responses. PT and SLA surfaces induce DCs mature, while DCs seeded on modSLA-Ti surface maintain an immature phenotype and exhibit a potential of promoting osteogenic differentiation of MC3T3-E1 cells.
Project description:To evaluate mRNA expression profile (transcriptome), we identified mRNAs of osteoblastic cells from human alveolar crest culture in contact with different titanium surfaces: control (polished), nanotextured (polished titanium discs, etching at 25oC with 50% H2SO4conc and 50% H2O2aq) , nano+submicrotextured (polished titanium discs, etching at 50oC with 50% H2SO4conc and 50% H2O2aq) and rough microtexture (polished titanium discs, etching at 50oC with 100% H2O2aq). The osteoblastic cells were cultured in the alpha-minimum essential medium, supplemented with fetal bovine serum, gentamicin, fungizone, dexamethasone, ascorbic acid and β-glycerophosphate. The mRNA expression profiling was analyzed through hybridizations with whole-human genome Agilent microarray (4x44K format).