Ontology highlight
ABSTRACT: Background
As lung cancer is one of the most significant factors seriously endangering human health, a robot-assisted puncture system with high accuracy and safety is urgently needed. The purpose of this investigation was to compare the safety and effectiveness of such a robot-assisted system to the conventional computed tomography (CT)-guided manual method for percutaneous lung biopsies (PLBs) in pigs.Methods
An optical navigation robot-assisted puncture system was developed and compared to the traditional CT-guided PLB using simulated lesions in experimental animals. A total of 30 pulmonary nodules were successfully created in 5 pigs (Wuzhishan pig, 1 male and 4 females). Of these, 15 were punctured by the optical navigation robot-assisted puncture system (robotic group), and 15 were manually punctured under CT guidance (manual group). The biopsy success rate, operation time, first needle tip-target point deviation, and needle adjustment times were compared between groups. Postoperative CT scans were performed to identify complications.Results
The single puncture success rate was higher in the robotic group (13/15; 86.7%) than in the manual group (8/15; 53.3%). The first puncture was closer to the target lesion (1.8±1.7 mm), and the operation time was shorter (7.1±3.7 minutes) in the robotic group than in the manual group (4.4±2.8 mm and 12.9±7.6 minutes, respectively). The angle deviation was smaller in the robotic group (3.26°±2.48°) than in the manual group (7.71°±3.86°). The robotic group displayed significant advantages (P<0.05). The primary complication in both groups was slight bleeding, with an incidence of 26.7% in the robotic group and 40.0% in the manual group. There was 1 case of pneumothorax in the manual group, and there were no deaths due to complications in either group.Conclusions
An optical navigation robot-assisted system for PLBs guided by CT images was developed and demonstrated. The experimental results indicate that the proposed system is accurate, efficient, and safe in pigs.
SUBMITTER: Li J
PROVIDER: S-EPMC10722077 | biostudies-literature | 2023 Dec
REPOSITORIES: biostudies-literature
Li Jing J Su Liyilei L Liu Jun J Peng Qian Q Xu Rongde R Cui Wei W Deng Yi Y Xie Weiguo W Huang Bingding B Chen Jingjing J
Quantitative imaging in medicine and surgery 20231010 12
<h4>Background</h4>As lung cancer is one of the most significant factors seriously endangering human health, a robot-assisted puncture system with high accuracy and safety is urgently needed. The purpose of this investigation was to compare the safety and effectiveness of such a robot-assisted system to the conventional computed tomography (CT)-guided manual method for percutaneous lung biopsies (PLBs) in pigs.<h4>Methods</h4>An optical navigation robot-assisted puncture system was developed and ...[more]