Oscillometry and spirometry are not interchangeable when assessing the bronchodilator response in children and young adults born preterm.


ABSTRACT:

Introduction

The European Respiratory Society Oscillometry Taskforce identified that clinical correlates of bronchodilator responses are needed to advance oscillometry in clinical practice. The understanding of bronchodilator-induced oscillometry changes in preterm lung disease is poor. Here we describe a comparison of bronchodilator assessments performed using oscillometry and spirometry in a population born very preterm and explore the relationship between bronchodilator-induced changes in respiratory function and clinical outcomes.

Methods

Participants aged 6-23 born ≤32 (N = 288; 132 with bronchopulmonary dysplasia) and ≥37 weeks' gestation (N = 76, term-born controls) performed spirometry and oscillometry. A significant bronchodilator response (BDR) to 400 μg salbutamol was classified according to published criteria.

Results

A BDR was identified in 30.9% (n = 85) of preterm-born individuals via spirometry and/or oscillometry, with poor agreement between spirometry and oscillometry definitions (k = 0.26; 95% confidence interval [CI] 0.18-0.40, p < .001). Those born preterm with a BDR by oscillometry but not spirometry had increased wheeze (33% vs. 11%, p = .010) and baseline resistance (Rrs5 z-score mean difference (MD) = 0.86, 95% CI 0.07-1.65, p = .025), but similar baseline spirometry to the group without a BDR (forced expiratory volume in 1 s [FEV1 ] z-score MD = -0.01, 95% CI -0.66 to 0.68, p > .999). Oscillometry was more feasible than spirometry (95% success rate vs. 85% (FEV1 ), 69% (forced vital capacity) success rate, p < .001), however being born preterm did not affect test feasibility.

Conclusion

In the preterm population, oscillometry is a feasible and clinically useful supportive test to assess the airway response to inhaled salbutamol. Changes measured by oscillometry reflect related but distinct physiological changes to those measured by spirometry, and thus these tests should not be used interchangeably.

SUBMITTER: Smith EF 

PROVIDER: S-EPMC10947568 | biostudies-literature | 2023 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Oscillometry and spirometry are not interchangeable when assessing the bronchodilator response in children and young adults born preterm.

Smith Elizabeth F EF   Bradshaw Tiffany K TK   Urs Rhea C RC   Evans Denby J DJ   Hemy Naomi R NR   Hall Graham L GL   Wilson Andrew C AC   Simpson Shannon J SJ  

Pediatric pulmonology 20230804 11


<h4>Introduction</h4>The European Respiratory Society Oscillometry Taskforce identified that clinical correlates of bronchodilator responses are needed to advance oscillometry in clinical practice. The understanding of bronchodilator-induced oscillometry changes in preterm lung disease is poor. Here we describe a comparison of bronchodilator assessments performed using oscillometry and spirometry in a population born very preterm and explore the relationship between bronchodilator-induced change  ...[more]

Similar Datasets

| S-EPMC5740078 | biostudies-literature
| S-EPMC6306484 | biostudies-literature
| S-EPMC6319724 | biostudies-literature
| S-EPMC3639498 | biostudies-literature
| S-EPMC4445394 | biostudies-literature
| S-EPMC7047464 | biostudies-literature
| S-EPMC9816170 | biostudies-literature
| S-EPMC11881051 | biostudies-literature
| S-EPMC7794670 | biostudies-literature
| S-EPMC6413301 | biostudies-literature