External Quality Assessment Program for SARS-COV-2 Molecular Detection in Pakistan.


ABSTRACT:

Introduction

Amid coronavirus disease 2019 (COVID-19) pandemic, accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for diagnosis management and breaking down transmission chains. We designed a national external quality assessment panel (EQAP) for SARS-CoV-2 molecular detection comprising working laboratories nationwide.

Methods

A molecular diagnostic EQA panel that consists of five samples for SARS CoV-2 testing was distributed to 141 public and private sector laboratories across country. These samples contain different concentrations of SARS-CoV-2 to evaluate the sensitivity of commercial kits available.

Results

Sensitivity among public and private sector laboratories was variable, particularly lower SARS-CoV-2 concentrations significantly increased the risk of false-negative tests, whereas Ct values of accurately tested SARS-CoV-2 specimens increased as concentration decreased. These findings highlighted that performance of used commercial kits was not significantly correlated to various extraction or PCR methods.

Conclusion

This study highlights the need for a national external quality assessment panel (EQAP) in the country to improve the quality of the healthcare system while ensuring the accuracy and reliability of results. Furthermore, EQAPs can help laboratories meet accreditation and regulatory requirements. However, continued participation in EQAP is recommended for quality enhancement of laboratories.

SUBMITTER: Badar N 

PROVIDER: S-EPMC11239755 | biostudies-literature | 2024 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

External Quality Assessment Program for SARS-COV-2 Molecular Detection in Pakistan.

Badar Nazish N   Ikram Aamer A   Salman Muhammad M   Saeed Sidra S   Mirza Hamza Ahmed HA   Ahad Abdul A   Ashraf Asiya A   Farooq Umer U  

Influenza and other respiratory viruses 20240701 7


<h4>Introduction</h4>Amid coronavirus disease 2019 (COVID-19) pandemic, accurate detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is critical for diagnosis management and breaking down transmission chains. We designed a national external quality assessment panel (EQAP) for SARS-CoV-2 molecular detection comprising working laboratories nationwide.<h4>Methods</h4>A molecular diagnostic EQA panel that consists of five samples for SARS CoV-2 testing was distributed to 141 pu  ...[more]

Similar Datasets

| S-EPMC7510727 | biostudies-literature
| S-EPMC7106428 | biostudies-literature
| S-EPMC10425338 | biostudies-literature
| S-EPMC7587075 | biostudies-literature
| S-EPMC8106723 | biostudies-literature
| S-EPMC9235289 | biostudies-literature
| S-EPMC3830650 | biostudies-literature
| S-EPMC7106520 | biostudies-literature
| S-EPMC11628893 | biostudies-literature
| S-EPMC4503447 | biostudies-literature