Separation of sub-micron particles from micron particles using acoustic fluid relocation combined with acoustophoresis.


ABSTRACT: Acoustophoresis has gained increasing attention as a gentle, non-contact, and high-throughput cell and particle separation technique. It is conveniently used to isolate and enrich particles that are greater than 2 ?m; however, its use in manipulating particles smaller than 2 ?m is limited. In this work, we present an alternative way of using acoustic forces to manipulate sub-micrometer particles in continuous flow fashion. It has been shown that acoustic forces can be employed to relocate parallel laminar flow streams of two impedance-mismatched fluids. We demonstrate the separation of sub-micron particles from micron particles by the combination of acoustophoresis and acoustic fluid relocation. The micron particles are focused into the middle of the flow channel via primary acoustic forces while sub-micron particles are moved to the side via drag forces created by the relocating fluid. We demonstrate the proof of the concept using binary mixtures of particles comprised of sub-micron/micron particles, micron/micron particles, and bovine red blood cells with E. coli. The efficiency of the particle enrichment is determined via flow cytometry analysis of the collected streams. This study demonstrates that by combining acoustic fluid relocation with acoustophoresis, sub-micron particles can be effectively separated from micron particles at high flow rates and it can be further implemented to separate binary mixtures of micron particles if the volumetric ratio of two particles is greater than 10 and the larger particle diameter is about 10 ?m. The combined method is more appropriate to use than acoustophoresis in situations where acoustic streaming and differences in acoustic impedance of fluids can be of concern. Graphical abstract In the presence of a resonance acoustic field, the clean high-density fluid (dark gray) and the low-density sample fluid are relocated. During this process, E. coli are separated from the red blood cells (RBCs).

SUBMITTER: Gautam GP 

PROVIDER: S-EPMC6143349 | biostudies-literature | 2018 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Separation of sub-micron particles from micron particles using acoustic fluid relocation combined with acoustophoresis.

Gautam Gayatri P GP   Gurung Rubi R   Fencl Frank A FA   Piyasena Menake E ME  

Analytical and bioanalytical chemistry 20180726 25


Acoustophoresis has gained increasing attention as a gentle, non-contact, and high-throughput cell and particle separation technique. It is conveniently used to isolate and enrich particles that are greater than 2 μm; however, its use in manipulating particles smaller than 2 μm is limited. In this work, we present an alternative way of using acoustic forces to manipulate sub-micrometer particles in continuous flow fashion. It has been shown that acoustic forces can be employed to relocate parall  ...[more]

Similar Datasets

| S-EPMC3070742 | biostudies-literature
| S-EPMC8267599 | biostudies-literature
| S-EPMC3078152 | biostudies-other
| S-EPMC6190034 | biostudies-literature
| S-EPMC7870900 | biostudies-literature
| S-EPMC8717332 | biostudies-literature
| S-EPMC9268962 | biostudies-literature