Unknown

Dataset Information

0

Are there differences among operators in false-negative rates of endosonography with needle aspiration for mediastinal nodal staging of non-small cell lung cancer?


ABSTRACT:

Background

Endosonography with needle aspiration (EBUS/EUS-NA) is recommended as the first choice for mediastinal nodal assessment in non-small cell lung cancer (NSCLC). It is important to maintain adequate negative predictive value of the procedure to avoid unnecessary additional surgical staging, but there are few studies on the influence of operator-related factors including competency on false negative results. This study aims to compare the false negative rate of individual operators and whether it changes according to accumulation of experience.

Methods

This is a retrospective study of NSCLC patients who were N0/N1 by EBUS/EUS-NA and confirmed by pathologic staging upon mediastinal lymph node dissection (n = 705). Patients were divided into a false negative group (finally confirmed as pN2/N3) and a true negative group (pN0/N1). False negative rates of six operators and whether these changed according to accumulated experience were analyzed.

Results

There were 111 (15.7%) false negative cases. False negative rates among six operators ranged from 8.3 to 21.4%; however, there were no statistical differences before and after adjustment for patient characteristics and procedure-related factors (P = 0.346 and P = 0.494, respectively). In addition, false negative rates did not change as each operator accumulated experience (P for trend = 0.632).

Conclusions

Our data suggest that there would be no difference in false negative rates regardless of which operator performs the procedure assuming that the operators have completed a certain period of observation and have performed procedures under the guidance of an expert.

SUBMITTER: Kim S 

PROVIDER: S-EPMC6332520 | biostudies-literature | 2019 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Are there differences among operators in false-negative rates of endosonography with needle aspiration for mediastinal nodal staging of non-small cell lung cancer?

Kim Sukyeon S   Shin Beomsu B   Lee Hyun H   Ha Jick Hwan JH   Lee Kyungjong K   Um Sang-Won SW   Kim Hojoong H   Jeong Byeong-Ho BH  

BMC pulmonary medicine 20190114 1


<h4>Background</h4>Endosonography with needle aspiration (EBUS/EUS-NA) is recommended as the first choice for mediastinal nodal assessment in non-small cell lung cancer (NSCLC). It is important to maintain adequate negative predictive value of the procedure to avoid unnecessary additional surgical staging, but there are few studies on the influence of operator-related factors including competency on false negative results. This study aims to compare the false negative rate of individual operator  ...[more]

Similar Datasets

| S-EPMC9168235 | biostudies-literature
| S-EPMC1747236 | biostudies-literature
| S-EPMC10713267 | biostudies-literature
| S-EPMC7326228 | biostudies-literature
| S-EPMC5542941 | biostudies-other
| S-EPMC7533300 | biostudies-literature
| S-EPMC8406242 | biostudies-literature
| S-EPMC8519150 | biostudies-literature
| S-EPMC3423452 | biostudies-literature
| S-EPMC7475585 | biostudies-literature