Pseudomonas poae-Associated Fatal Septic Transfusion Reaction, Peoria, Illinois, USA, 2017.
Ontology highlight
ABSTRACT: In the United States, fatal transfusion-transmitted infections from red blood cell units are rare. Although this pattern mostly reflects how inhospitable refrigerated red blood cell units are to contaminant growth, fatalities caused by microorganisms that can grow at storage temperature (4°C), but not in standard clinical blood cultures at 37°C, are probably underestimated. We analyzed a fatal red blood cell transfusion in Peoria, Illinois, USA, that occurred in 2017. Samples from the patient's whole blood and the red blood cell unit remained culture-negative during the investigation, despite direct visualization of gram-negative bacilli within the unit immediately after transfusion. We identified the bacteria as Pseudomonas poae, a nonpathogenic pseudomonad carrying multiple cold-shock do
SUBMITTER: Woodring TS
PROVIDER: S-EPMC6649322 | biostudies-literature | 2019 Aug
REPOSITORIES: biostudies-literature