Unknown

Dataset Information

Differences in the performance of resuscitation according to the resuscitation guideline terminology during infant cardiopulmonary resuscitation: "Approximately 4 cm" versus "at least one-third the anterior-posterior diameter of the chest".


ABSTRACT: AIM:This study was conducted to investigate the effect of resuscitation guideline terminology on the performance of infant cardiopulmonary resuscitation (CPR). METHODS:A total of 40 intern or resident physicians conducted 2-min CPR with the two-finger technique (TFT) and two-thumb technique (TT) on a simulated infant cardiac arrest model with a 1-day interval. They were randomly assigned to Group A or B. The participants of Group A conducted CPR with the chest compression depth (CCD) target of "approximately 4 cm" and those of Group B conducted CPR with the CCD target of "at least one-third the anterior-posterior diameter of the chest". Single rescuer CPR was performed with a 15:2 compression to ventilation ratio on the floor. RESULTS:In both chest compression techniques, the average CCD o

SUBMITTER: Lee W 

PROVIDER: S-EPMC7092967 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications