Unknown

Dataset Information

0

MR fingerprinting ASL: Sequence characterization and comparison with dynamic susceptibility contrast (DSC) MRI.


ABSTRACT: MR Fingerprinting (MRF)-based Arterial-Spin-Labeling (ASL) has the potential to measure multiple parameters such as cerebral blood flow (CBF), bolus arrival time (BAT), and tissue T1 in a single scan. However, the previous reports have only demonstrated a proof-of-principle of the technique but have not examined the performance of the sequence in the context of key imaging parameters. Furthermore, there has not been a study to directly compare the technique to clinically used perfusion method of dynamic-susceptibility-contrast (DSC) MRI. The present report consists of two studies. In the first study (N = 8), we examined the dependence of MRF-ASL sequence on TR time pattern. Ten different TR patterns with a range of temporal characteristics were examined by both simulations and experiments. The results revealed that there was a significance dependence of the sequence performance on TR pattern (p < 0.001), although there was not a single pattern that provided dramatically improvements. Among the TR patterns tested, a sinusoidal pattern with a period of 125 TRs provided an overall best estimation in terms of spatial consistency. These experimental observations were consistent with those of numerical simulations. In the second study (N = 8), we compared MRF-ASL results with those of DSC MRI. It was found that MRF-ASL and DSC MRI provided highly comparable maps of cerebral blood flow (CBF) and bolus-arrival-time (BAT), with spatial correlation coefficients of 0.79 and 0.91, respectively. However, in terms of quantitative values, BAT obtained with MRF-ASL was considerably lower than that from DSC (p < 0.001), presumably because of the differences in tracer characteristics in terms of diffusible versus intravascular tracers. Test-retest assessment of MRF-ASL MRI revealed that the spatial correlations of parametric maps were 0.997, 0.962, 0.746 and 0.863 for B1 + , T1 , CBF, and BAT, respectively. MRF-ASL is a promising technique for assessing multiple perfusion parameters simultaneously without contrast agent.

SUBMITTER: Su P 

PROVIDER: S-EPMC7229700 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC5484761 | biostudies-literature
| S-EPMC7964869 | biostudies-literature
| S-EPMC8113983 | biostudies-literature
| S-EPMC6934650 | biostudies-literature
| S-EPMC8566029 | biostudies-literature
| S-EPMC3743424 | biostudies-literature
| S-EPMC6034979 | biostudies-literature
| S-EPMC6538021 | biostudies-literature
| S-EPMC2657863 | biostudies-other
| S-EPMC9731243 | biostudies-literature