Enhancement of signal-to-noise ratio for fluorescence endoscope image based on fast digital lock-in algorithm.


ABSTRACT: In this paper, the signal-to-noise ratios (SNR) of two image channels were enhanced with the fast digital lock-in algorithm. In order to simultaneously improve the quality of white and fluorescence images obtained by fluorescence endoscope, and improve the SNR to achieve a better image processing effect, two sources of white light and near-infrared light of a fluorescence endoscope were modulated, then the acquired images were demodulated into white and fluorescence images. A fluorescent endoscope experimental platform was setup to acquire endoscopic images of a target dyed by indocyanine green. The experimental results showed that the SNR of white and fluorescent images without the lock-in algorithm were 36.56 dB and 33.47 dB, respectively. However, with the lock-in algorithm, the SNR of white and fluorescent images were 39.54 dB and 35.70 dB, respectively. The SNR of white and fluorescent images was increased by 8.2% and 6.7%, respectively, by appling the digital lock-in algorithm. Therefore, this novel fluorescence endoscope based on the fast digital lock-in algorithm can rapidly and simultaneously obtain two-channel images of white light and fluorescence, effectively enhance the SNR of white and fluorescent images, and improve the imaging quality.

SUBMITTER: Wang H 

PROVIDER: S-EPMC8074948 | biostudies-literature | 2021 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Enhancement of signal-to-noise ratio for fluorescence endoscope image based on fast digital lock-in algorithm.

Wang Huiquan H   Hu Meng M   Xia Fang F   Guo Meng M   Zhang Shengzhao S   Zhao Zhe Z   Han Guang G   Wang Jinhai J  

Royal Society open science 20210310 3


In this paper, the signal-to-noise ratios (SNR) of two image channels were enhanced with the fast digital lock-in algorithm. In order to simultaneously improve the quality of white and fluorescence images obtained by fluorescence endoscope, and improve the SNR to achieve a better image processing effect, two sources of white light and near-infrared light of a fluorescence endoscope were modulated, then the acquired images were demodulated into white and fluorescence images. A fluorescent endosco  ...[more]

Similar Datasets

| S-EPMC7139168 | biostudies-literature
| S-EPMC3808417 | biostudies-other
| S-EPMC11650625 | biostudies-literature
| S-EPMC5862973 | biostudies-literature
| S-EPMC4229364 | biostudies-literature
| S-EPMC11427441 | biostudies-literature
| S-EPMC9418886 | biostudies-literature
| S-EPMC6941997 | biostudies-literature
| S-EPMC4466709 | biostudies-literature
| S-EPMC5444056 | biostudies-literature