Unknown

Dataset Information

0

Accuracy of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for direct bacterial identification from culture-positive urine samples.


ABSTRACT:

Background

Urinary tract infection (UTI) is one of the most frequent reasons for antimicrobial therapy. In typical clinical setting, 18-48 h is needed to identify pathogens by urine culture. A rapid method for pathogenic UTI diagnosis by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been developed in recent years.

Methods

This meta-analysis systematically evaluated the accuracy of MALDI-TOF MS for direct identification of bacteria from culture-positive urine samples. We queried the electronic database of Medline and Web of Science to obtain relevant articles.

Results

Nineteen articles involving 4,579 isolates were included after final selection in the meta-analysis. The random-effects pooled identification accuracy of MALDI-TOF MS was 0.82 with 95% confidence interval of 0.79 to 0.86 at the species level. For Gram-negative isolates, the correct identification performance of the species ranged from 0.54 to 0.98, with a cumulative rate of 0.87 (95% CI: 0.83 to 0.91). For Gram-positive isolates, the correct identification rate ranged from 0.32 to 0.80, with a cumulative rate of 0.59 (95% CI: 0.49 to 0.68).

Conclusions

MALDI-TOF MS provides a reliable direct identification of bacteria, particularly in cases of Gram-negative isolates, from clinical urine specimens. Nevertheless, the identification accuracy of this method is moderate for Gram-positive bacteria.

SUBMITTER: Sun B 

PROVIDER: S-EPMC8106043 | biostudies-literature | 2021 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of matrix-assisted laser desorption ionization time-of-flight mass spectrometry for direct bacterial identification from culture-positive urine samples.

Sun Bin B   Wang Wei W   Ma Ping P   Gu Bing B  

Annals of translational medicine 20210401 8


<h4>Background</h4>Urinary tract infection (UTI) is one of the most frequent reasons for antimicrobial therapy. In typical clinical setting, 18-48 h is needed to identify pathogens by urine culture. A rapid method for pathogenic UTI diagnosis by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been developed in recent years.<h4>Methods</h4>This meta-analysis systematically evaluated the accuracy of MALDI-TOF MS for direct identification of bacteria  ...[more]

Similar Datasets

| S-EPMC5686160 | biostudies-literature
| S-EPMC2830621 | biostudies-literature
| S-EPMC8096114 | biostudies-literature
| S-EPMC6787577 | biostudies-literature
| S-EPMC5703816 | biostudies-literature
| S-EPMC4313279 | biostudies-literature
| S-EPMC4524100 | biostudies-literature
| S-EPMC4633522 | biostudies-literature
| S-EPMC1151883 | biostudies-literature
| S-EPMC4097711 | biostudies-literature