Unknown

Dataset Information

0

Validation of High-Sensitivity Severe Acute Respiratory Syndrome Coronavirus 2 Testing for Stool-Toward the New Normal for Fecal Microbiota Transplantation.


ABSTRACT:

Introduction

Mounting evidence demonstrates potential for fecal-oral transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The US Food and Drug Administration now requires SARS-CoV-2 testing of potential feces donors before the use of stool manufactured for fecal microbiota transplantation. We sought to develop and validate a high-sensitivity SARS-CoV-2 reverse transcriptase polymerase chain reaction (RT-PCR) procedure for testing stool specimens.

Methods

A modified extraction method was used with an RT-PCR assay adapted from the Centers for Disease Control and Prevention PCR protocol for respiratory specimens. Contrived specimens were created using pre-COVID-19 banked stool specimens and spiking in known concentrations of SARS-CoV-2-specific nucleic acid. The highest transcript concentration at which 2/2 or 1/2 SARS-CoV-2 targets were detected in 9/10 replicates was defined as the dual-target limit and single-target limit of detection, respectively. The clinical performance of the assay was evaluated with stool samples collected from 17 nasopharyngeal swab RT-PCR-positive patients and 14 nasopharyngeal RT-PCR-negative patients.

Results

The dual-target and single-target limit of detection were 56 copies/μL and 3 copies/μL, respectively. SARS-CoV-2 was detected at concentrations as low as 0.6 copies/μL. Clinical stool samples from known COVID-19-positive patients demonstrated the detection of SARS-CoV-2 in stool up to 29 days from symptom onset with a high agreement with nasopharyngeal swab tests (kappa statistic of 0.95, P value < 0.001).

Discussion

The described RT-PCR test is a sensitive and flexible approach for the detection of SARS-CoV-2 in stool specimens. We propose an integrated screening approach that incorporates this stool test to support continuation of fecal microbiota transplantation programs.

SUBMITTER: Babiker A 

PROVIDER: S-EPMC8189625 | biostudies-literature | 2021 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of High-Sensitivity Severe Acute Respiratory Syndrome Coronavirus 2 Testing for Stool-Toward the New Normal for Fecal Microbiota Transplantation.

Babiker Ahmed A   Ingersoll Jessica M JM   Adelman Max W MW   Webster Andrew S AS   Broder Kari J KJ   Stittleburg Victoria V   Waggoner Jesse J JJ   Kraft Colleen S CS   Woodworth Michael H MH  

Clinical and translational gastroenterology 20210609 6


<h4>Introduction</h4>Mounting evidence demonstrates potential for fecal-oral transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The US Food and Drug Administration now requires SARS-CoV-2 testing of potential feces donors before the use of stool manufactured for fecal microbiota transplantation. We sought to develop and validate a high-sensitivity SARS-CoV-2 reverse transcriptase polymerase chain reaction (RT-PCR) procedure for testing stool specimens.<h4>Methods</h4>A  ...[more]

Similar Datasets

| S-EPMC7867714 | biostudies-literature
| S-EPMC8082449 | biostudies-literature
| S-EPMC5265816 | biostudies-literature
| S-EPMC7665722 | biostudies-literature
| S-EPMC6586871 | biostudies-literature
| S-EPMC4072236 | biostudies-other
| S-EPMC8501685 | biostudies-literature
| S-EPMC9748282 | biostudies-literature
2025-04-30 | GSE271297 | GEO
| S-EPMC6724572 | biostudies-literature