Unknown

Dataset Information

0

Comparison of Non-Invasive Clinical Algorithms for Liver Fibrosis in Patients With Chronic Hepatitis B to Reduce the Need for Liver Biopsy: Application of Enhanced Liver Fibrosis and Mac-2 Binding Protein Glycosylation Isomer.


ABSTRACT:

Background

Non-invasive clinical algorithms for the detection of liver fibrosis (LF) can reduce the need for liver biopsy (LB). We explored the implementation of two serum biomarkers, enhanced liver fibrosis (ELF) and Mac-2 binding protein glycosylation isomer (M2BPGi), in clinical algorithms for LF in chronic hepatitis B (CHB) patients.

Methods

Two clinical algorithms were applied to 152 CHB patients: (1) transient elastography (TE) followed by biomarkers (TE/ELF and TE/M2GPGi); (2) biomarker test followed by TE (ELF/TE and M2BPGi/TE). Using the cut-off value or index for the detection of advanced LF (TE≥F3; 9.8 in ELF and 3.0 in M2BPGi), LB was expected to be performed in cases with discordant TE and biomarker results.

Results

In both algorithms, the expected number of LBs was lower when using M2BPGi than when using ELF (TE/ELF or ELF/TE, 13.2% [N=20]; TE/M2BPGi or M2BPGi/TE, 9.9% [N=15]), although there was no statistical difference (P=0.398). In the TE low-risk group (TE≤F2), the discordance rate was significantly lower in the TE/M2BPGi approach than in the TE/ELF approach (1.5% [2/136] vs. 11.0% [15/136], P=0.002). In the biomarker low-risk group, there was no significant difference between the ELF/TE and M2BPGi/TE approaches (3.9% [5/126] vs. 8.8% [13/147], P=0.118).

Conclusions

Both ELF and M2BPGi can be implemented in non-invasive clinical algorithms for assessing LF in CHB patients. Given the lowest possibility of losing advanced LF cases in the low-risk group when using the TE/M2BPGi approach, this combination seems useful in clinical practice.

SUBMITTER: Hur M 

PROVIDER: S-EPMC8548241 | biostudies-literature | 2022 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of Non-Invasive Clinical Algorithms for Liver Fibrosis in Patients With Chronic Hepatitis B to Reduce the Need for Liver Biopsy: Application of Enhanced Liver Fibrosis and Mac-2 Binding Protein Glycosylation Isomer.

Hur Mina M   Park Mikyoung M   Moon Hee-Won HW   Choe Won Hyeok WH   Lee Chae Hoon CH  

Annals of laboratory medicine 20220301 2


<h4>Background</h4>Non-invasive clinical algorithms for the detection of liver fibrosis (LF) can reduce the need for liver biopsy (LB). We explored the implementation of two serum biomarkers, enhanced liver fibrosis (ELF) and Mac-2 binding protein glycosylation isomer (M2BPGi), in clinical algorithms for LF in chronic hepatitis B (CHB) patients.<h4>Methods</h4>Two clinical algorithms were applied to 152 CHB patients: (1) transient elastography (TE) followed by biomarkers (TE/ELF and TE/M2GPGi);  ...[more]

Similar Datasets

| S-EPMC9653177 | biostudies-literature
| S-EPMC5895862 | biostudies-literature
| S-EPMC9575787 | biostudies-literature
| S-EPMC10271221 | biostudies-literature
| S-EPMC7519502 | biostudies-literature
| S-EPMC11534790 | biostudies-literature
| S-EPMC6442699 | biostudies-literature
| S-EPMC8516253 | biostudies-literature
| S-EPMC8079659 | biostudies-literature
| S-EPMC9599873 | biostudies-literature