Absence of first-pass isolation is associated with poor pulmonary vein isolation durability and atrial fibrillation ablation outcomes.


ABSTRACT:

Background

Pulmonary vein (PV) reconnection is the main cause of atrial fibrillation (AF) recurrence. This study aimed to examine the effect of first-pass PV isolation (PVI) on PV reconnection frequency during the procedure and on AF ablation outcomes.

Methods

This retrospective study included 446 patients with drug-refractory AF (370 men, aged 64 ± 10 years) who underwent initial PVI using an open-irrigated contact force catheter between January 2015 and October 2016. We investigated the effect of first-pass PVI on PV reconnection during spontaneous PV reconnection and dormant conduction after an adenosine triphosphate challenge.

Results

First-pass PVI was achieved in 69% (617/892) of ipsilateral PVs, of which we observed PV reconnection during the procedure in 134 (22%) PVs. This value was significantly lower than that observed in those without first-pass PVI (50%, 138/275) (P < .0001). We divided the subjects into two groups based on the presence or absence of first-pass PVI in at least one of two ipsilateral PVs: first-pass (n = 383, 86%) and non-first-pass groups (n = 63, 14%). The 2-year AF recurrence-free rate was significantly higher in the first-pass group than in the other group (75% vs 59%, log-rank P = .032). In 78 patients with repeat AF ablation, the PV reconnection rate in the second procedure was significantly lower in PVs that had first-pass isolation in the first procedure (34% vs 73%, P < .0001).

Conclusions

Absence of first-pass PVI was associated with a higher frequency of spontaneous PV reconnection and dormant conduction and poor ablation outcomes. First-pass isolation may be a useful marker for better PVI durability.

SUBMITTER: Ninomiya Y 

PROVIDER: S-EPMC8637089 | biostudies-literature | 2021 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Absence of first-pass isolation is associated with poor pulmonary vein isolation durability and atrial fibrillation ablation outcomes.

Ninomiya Yuichi Y   Inoue Koichi K   Tanaka Nobuaki N   Okada Masato M   Tanaka Koji K   Onishi Toshinari T   Hirao Yuko Y   Oka Takafumi T   Inoue Hiroyuki H   Takayasu Kohtaro K   Nakamaru Ryo R   Kitagaki Ryo R   Koyama Yasushi Y   Okamura Atsunori A   Iwakura Katsuomi K   Ohishi Mitsuru M   Fujii Kenshi K  

Journal of arrhythmia 20210906 6


<h4>Background</h4>Pulmonary vein (PV) reconnection is the main cause of atrial fibrillation (AF) recurrence. This study aimed to examine the effect of first-pass PV isolation (PVI) on PV reconnection frequency during the procedure and on AF ablation outcomes.<h4>Methods</h4>This retrospective study included 446 patients with drug-refractory AF (370 men, aged 64 ± 10 years) who underwent initial PVI using an open-irrigated contact force catheter between January 2015 and October 2016. We investig  ...[more]

Similar Datasets

| S-EPMC9347196 | biostudies-literature
| S-EPMC10664405 | biostudies-literature
| S-EPMC7252765 | biostudies-literature
| S-EPMC8427383 | biostudies-literature
| S-EPMC11508299 | biostudies-literature
| S-EPMC10241727 | biostudies-literature
| S-EPMC7524096 | biostudies-literature
| S-EPMC9550675 | biostudies-literature
| S-EPMC7514301 | biostudies-literature