Unknown

Dataset Information

0

Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer.


ABSTRACT: A lens-based Raman spectrometer is characterized by studying the optical elements in the optical path and we study the measure of aberration-diffraction effects. This is achieved by measuring the spectral resolution (SR) thus encompassing almost all optical elements of a spectrometer that are mostly responsible for such effects. An equation for SR is used to determine the quality factor Q which measures aberration/diffraction effects occurring in a spectrometer. We show how the quality factor changes with different spectrometer parameters such as grating groove density, the wavelength of excitation, pinhole width, charge-coupled device (CCD) pixel density, etc. This work provides an insight into the quality of a spectrometer and helps to monitor the performance of the spectrometer over a certain period. Commercially available spectrometers or home-built spectrometers are prone to misalignment in optical elements and can benefit from this work that allows maintaining the overall quality of the setup. Performing such experiments over a period helps to minimize the aberration/diffraction effects occurring as a result of time and maintaining the quality of measurements.

SUBMITTER: Mukherjee A 

PROVIDER: S-EPMC8832553 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Determination and Monitoring of Quality Parameters: A Detailed Study of Optical Elements of a Lens-Based Raman Spectrometer.

Mukherjee Ashutosh A   Lorenz Anita A   Brecht Marc M  

Applied spectroscopy 20211029 2


A lens-based Raman spectrometer is characterized by studying the optical elements in the optical path and we study the measure of aberration-diffraction effects. This is achieved by measuring the spectral resolution (SR) thus encompassing almost all optical elements of a spectrometer that are mostly responsible for such effects. An equation for SR is used to determine the quality factor <i>Q</i> which measures aberration/diffraction effects occurring in a spectrometer. We show how the quality fa  ...[more]

Similar Datasets

| S-EPMC7366627 | biostudies-literature
| S-EPMC9929119 | biostudies-literature
| S-EPMC3218359 | biostudies-literature
| S-EPMC6999873 | biostudies-literature
| S-EPMC7436060 | biostudies-literature
| PRJEB59025 | ENA
| PRJEB59061 | ENA
| S-EPMC10251777 | biostudies-literature
| S-EPMC7663837 | biostudies-literature
| PRJEB36483 | ENA