ABSTRACT: Objectives
To propose and validate a reliable semi-automatic approach for three-dimensional (3D) analysis of the upper airway (UA) based on voxel-based registration (VBR).Methods
Post-operative cone beam computed tomography (CBCT) scans of 10 orthognathic surgery patients were superimposed to the pre-operative CBCT scans by VBR using the anterior cranial base as reference. Anatomic landmarks were used to automatically cut the UA and calculate volumes and cross-sectional areas (CSA). The 3D analysis was performed by two observers twice, at an interval of two weeks. Intraclass correlations and Bland-Altman plots were used to quantify the measurement error and reliability of the method. The relative Dahlberg error was calculated and compared with a similar method based on landmark re-identification and manual measurements.Results
Intraclass correlation coefficient (ICC) showed excellent intra- and inter-observer reliability (ICC ≥ 0.995). Bland-Altman plots showed good observer agreement, low bias and no systematic errors. The relative Dahlberg error ranged between 0.51 and 4.30% for volume and 0.24 and 2.90% for CSA. This was lower when compared with a similar, manual method. Voxel-based registration introduced 0.05-1.44% method error.Conclusions
The proposed method was shown to have excellent reliability and high observer agreement. The method is feasible for longitudinal clinical trials on large cohorts due to being semi-automatic.
SUBMITTER: Diaconu A
PROVIDER: S-EPMC8925868 | biostudies-literature | 2022 Mar
REPOSITORIES: biostudies-literature

Dento maxillo facial radiology 20211108 3
<h4>Objectives</h4>To propose and validate a reliable semi-automatic approach for three-dimensional (3D) analysis of the upper airway (UA) based on voxel-based registration (VBR).<h4>Methods</h4>Post-operative cone beam computed tomography (CBCT) scans of 10 orthognathic surgery patients were superimposed to the pre-operative CBCT scans by VBR using the anterior cranial base as reference. Anatomic landmarks were used to automatically cut the UA and calculate volumes and cross-sectional areas (CS ...[more]