T1ρ for Radiotherapy Treatment Response Monitoring in Rectal Cancer Patients: A Pilot Study.


ABSTRACT: Quantitative MRI has the potential to produce imaging biomarkers for the prediction of early response to radiotherapy treatment. In this pilot study, a potential imaging biomarker, the T1ρ relaxation time, is assessed for this purpose. A T1ρ sequence was implemented on a 1.5 T MR-linac system, a system that combines an MRI with a linear accelerator for radiation treatment. An agar phantom with concentrations of 1-4% w/w was constructed for technical validation of the sequence. Phantom images were assessed in terms of short-term repeatability and signal-to-noise ratio. Twelve rectal cancer patients, who were treated with 5 × 5 Gy, were imaged on each treatment fraction. Individual changes in the T1ρ values of the gross tumor volume (GTV) showed an increase for most patients, although a paired t-test comparing values in the GTV from the first to the last treatment fraction showed no statistically significant difference. The phantom measurements showed excellent short-term repeatability (0.5-1.5 ms), and phantom T1ρ values corresponded to the literature values. T1ρ imaging was implemented successfully on the MR-linac, with a repeatability comparable to diagnostic systems, although clinical benefit in terms of treatment response monitoring remains to be demonstrated.

SUBMITTER: Kooreman ES 

PROVIDER: S-EPMC8999631 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

T<sub>1ρ</sub> for Radiotherapy Treatment Response Monitoring in Rectal Cancer Patients: A Pilot Study.

Kooreman Ernst S ES   Tanaka Max M   Ter Beek Leon C LC   Peters Femke P FP   Marijnen Corrie A M CAM   van der Heide Uulke A UA   van Houdt Petra J PJ  

Journal of clinical medicine 20220402 7


Quantitative MRI has the potential to produce imaging biomarkers for the prediction of early response to radiotherapy treatment. In this pilot study, a potential imaging biomarker, the T<sub>1ρ</sub> relaxation time, is assessed for this purpose. A T<sub>1ρ</sub> sequence was implemented on a 1.5 T MR-linac system, a system that combines an MRI with a linear accelerator for radiation treatment. An agar phantom with concentrations of 1-4% <i>w</i>/<i>w</i> was constructed for technical validation  ...[more]

Similar Datasets

| S-EPMC8010550 | biostudies-literature
| S-EPMC6993432 | biostudies-literature
| S-EPMC3299656 | biostudies-literature
| S-EPMC3299656 | biostudies-literature
| S-EPMC3383178 | biostudies-literature
2025-03-23 | PXD062156 |
| S-EPMC10078624 | biostudies-literature
2011-12-12 | GSE26027 | GEO
2011-12-12 | E-GEOD-26027 | biostudies-arrayexpress
| S-EPMC5790354 | biostudies-literature