Unknown

Dataset Information

0

Low-fouling CNT-PEG-hydrogel coated quartz crystal microbalance sensor for saliva glucose detection.


ABSTRACT: Saliva glucose detection based on a quartz crystal microbalance (QCM) sensor has emerged as a promising tool and a non-invasive diagnostic technique for diabetes. However, the low glucose concentration and strong protein interference in the saliva hinder the QCM sensors from practical applications. In this study, we present a robust and simple anti-fouling CNT-PEG-hydrogel film-coated QCM sensor for the detection of saliva glucose with high sensitivity. The CNT-PEG-hydrogel film consists of two layers; the bottom base PBA-hydrogel film is designed to recognize the glucose while the top CNT-PEG layer is used to restrict protein adsorption and improve the biocompatibility. Our results show that this CNT-PEG-hydrogel film exhibited a 10-fold enhancement on the detection limit compared to the PBA-hydrogel. Meanwhile, the adsorption of proteins on the surface of the CNT-PEG-hydrogel film, including bovine serum albumin (BSA), mucin (MUC), and fibrinogen (FIB), were reduced by 99.1%, 77.8%, and 83.7%, respectively. The CNT-PEG-hydrogel film could detect the typical saliva glucose level (0-50 mg L-1) in 10% saliva with a good responsivity. To sum up, this new tool with low-fouling film featuring high stability, specificity, and selectivity holds great potential for non-invasive monitoring of saliva glucose in human physiological levels.

SUBMITTER: Wang S 

PROVIDER: S-EPMC9034414 | biostudies-literature | 2021 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low-fouling CNT-PEG-hydrogel coated quartz crystal microbalance sensor for saliva glucose detection.

Wang Shiwen S   Liu Guanjiang G   Yang Bei B   Zhang Zifeng Z   Hu Debo D   Wu Chenchen C   Qin Yaling Y   Dou Qian Q   Dai Qing Q   Hu Wenping W  

RSC advances 20210628 37


Saliva glucose detection based on a quartz crystal microbalance (QCM) sensor has emerged as a promising tool and a non-invasive diagnostic technique for diabetes. However, the low glucose concentration and strong protein interference in the saliva hinder the QCM sensors from practical applications. In this study, we present a robust and simple anti-fouling CNT-PEG-hydrogel film-coated QCM sensor for the detection of saliva glucose with high sensitivity. The CNT-PEG-hydrogel film consists of two  ...[more]

Similar Datasets

| S-EPMC10302850 | biostudies-literature
| S-EPMC8544454 | biostudies-literature
| S-EPMC9075945 | biostudies-literature
| S-EPMC7676330 | biostudies-literature
| S-EPMC9221410 | biostudies-literature
| S-EPMC7482089 | biostudies-literature
| S-EPMC7037595 | biostudies-literature
| S-EPMC9049092 | biostudies-literature
| S-EPMC9118674 | biostudies-literature
| S-EPMC10705953 | biostudies-literature