Unknown

Dataset Information

0

A sensitive electrochemical sensor based on ZIF-8-acetylene black-chitosan nanocomposites for rutin detection.


ABSTRACT: Herein, we fabricated a sensitive rutin electrochemical sensor via modifying glassy carbon electrode (GCE) with zeolitic imidazolate framework-8 (ZIF-8) and acetylene black (AB) in the presence of chitosan (CS). The electrochemical activity and experimental parameters of the ZIF-8-AB-CS/GCE sensor were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Under the optimal conditions, the sensor presented a reasonable linear response in the range of 0.1-10 μM with a limit of detection (LOD) as low as 0.004 μM (S/N = 3). The sensor possessed good reproducibility and high stability, and was successfully applied to detect rutin tablet samples with satisfactory results, which was attributed to the synergistic effect between ZIF-8 and AB. Meanwhile, the sensor displayed a potential application for detection of other analytes in real samples. Furthermore, a probable interaction mechanism was proposed to account for the interaction between rutin and the nanocomposite electrode, which was not discussed in previous reports.

SUBMITTER: Jin YF 

PROVIDER: S-EPMC9086340 | biostudies-literature | 2018 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

A sensitive electrochemical sensor based on ZIF-8-acetylene black-chitosan nanocomposites for rutin detection.

Jin Ya-Feng YF   Ge Chuang-Ye CY   Li Xiao-Bo XB   Zhang Miao M   Xu Guang-Ri GR   Li Dong-Hao DH  

RSC advances 20180921 57


Herein, we fabricated a sensitive rutin electrochemical sensor <i>via</i> modifying glassy carbon electrode (GCE) with zeolitic imidazolate framework-8 (ZIF-8) and acetylene black (AB) in the presence of chitosan (CS). The electrochemical activity and experimental parameters of the ZIF-8-AB-CS/GCE sensor were investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Under the optimal conditions, the sensor presented a reasonable linear response in the range of 0.1  ...[more]

Similar Datasets

| S-EPMC9571638 | biostudies-literature
| S-EPMC6987276 | biostudies-literature
| S-EPMC10239869 | biostudies-literature
| S-EPMC9221106 | biostudies-literature
| S-EPMC10493855 | biostudies-literature
| S-EPMC10143982 | biostudies-literature
| S-EPMC9954471 | biostudies-literature
| S-EPMC10137692 | biostudies-literature
| S-EPMC10795129 | biostudies-literature
| S-EPMC11475201 | biostudies-literature