Ambulatory Cardiovascular Monitoring Via a Machine-Learning-Assisted Textile Triboelectric Sensor.


ABSTRACT: Wearable bioelectronics for continuous and reliable pulse wave monitoring against body motion and perspiration remains a great challenge and highly desired. Here, a low-cost, lightweight, and mechanically durable textile triboelectric sensor that can convert subtle skin deformation caused by arterial pulsatility into electricity for high-fidelity and continuous pulse waveform monitoring in an ambulatory and sweaty setting is developed. The sensor holds a signal-to-noise ratio of 23.3 dB, a response time of 40 ms, and a sensitivity of 0.21 µA kPa-1 . With the assistance of machine learning algorithms, the textile triboelectric sensor can continuously and precisely measure systolic and diastolic pressure, and the accuracy is validated via a commercial blood pressure cuff at the hospital. Additionally, a customized cellphone application (APP) based on built-in algorithm is developed for one-click health data sharing and data-driven cardiovascular diagnosis. The textile triboelectric sensor enabled wireless biomonitoring system is expected to offer a practical paradigm for continuous and personalized cardiovascular system characterization in the era of the Internet of Things.

SUBMITTER: Fang Y 

PROVIDER: S-EPMC9205313 | biostudies-literature | 2021 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ambulatory Cardiovascular Monitoring Via a Machine-Learning-Assisted Textile Triboelectric Sensor.

Fang Yunsheng Y   Zou Yongjiu Y   Xu Jing J   Chen Guorui G   Zhou Yihao Y   Deng Weili W   Zhao Xun X   Roustaei Mehrdad M   Hsiai Tzung K TK   Chen Jun J  

Advanced materials (Deerfield Beach, Fla.) 20210831 41


Wearable bioelectronics for continuous and reliable pulse wave monitoring against body motion and perspiration remains a great challenge and highly desired. Here, a low-cost, lightweight, and mechanically durable textile triboelectric sensor that can convert subtle skin deformation caused by arterial pulsatility into electricity for high-fidelity and continuous pulse waveform monitoring in an ambulatory and sweaty setting is developed. The sensor holds a signal-to-noise ratio of 23.3 dB, a respo  ...[more]

Similar Datasets

| S-EPMC11904663 | biostudies-literature
| S-EPMC11543809 | biostudies-literature
| S-EPMC7069695 | biostudies-literature
| S-EPMC7375248 | biostudies-literature
| S-EPMC10421034 | biostudies-literature
| S-EPMC10080540 | biostudies-literature
| S-EPMC8187499 | biostudies-literature
| S-EPMC7958622 | biostudies-literature
| S-EPMC11667019 | biostudies-literature