Unknown

Dataset Information

0

Glycemic Variability Assessment with a 14-Day Continuous Glucose Monitoring System: When and How Long to Measure MAGE (Mean Amplitude of Glucose Excursion) for Optimal Reliability?


ABSTRACT: Mean amplitude of glucose excursion (MAGE) is considered as the "gold standard" for assessing the short-term within-day glycemic variability (GV), which is an important component of overall glycemic control. A 14-day continuous glucose monitoring system is now widely used and allows easier assessment of GV. However, it is still unknown whether MAGE, usually calculated on a 48-hour period is identical whatever the time during the 14-day lifespan of the sensor and whether a longer time period might give additional information. We evaluated in 68 patients with type 1 diabetes, MAGE during three 2-day periods (day1-day3; day6-day8; day11-day13) and during periods of 3 days and 4 days. MAGE calculated at the three 2-day periods were identical and not different from MAGE of the 3-day or 4-day periods.

SUBMITTER: Verges B 

PROVIDER: S-EPMC9264451 | biostudies-literature | 2022 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Glycemic Variability Assessment with a 14-Day Continuous Glucose Monitoring System: When and How Long to Measure MAGE (Mean Amplitude of Glucose Excursion) for Optimal Reliability?

Vergès Bruno B   Pignol Elise E   Rouland Alexia A   Bouillet Benjamin B   Baillot-Rudoni Sabine S   Quilot Emilienne E   Djeffal Abdelmadjid A   Petit Jean Michel JM  

Journal of diabetes science and technology 20210210 4


Mean amplitude of glucose excursion (MAGE) is considered as the "gold standard" for assessing the short-term within-day glycemic variability (GV), which is an important component of overall glycemic control. A 14-day continuous glucose monitoring system is now widely used and allows easier assessment of GV. However, it is still unknown whether MAGE, usually calculated on a 48-hour period is identical whatever the time during the 14-day lifespan of the sensor and whether a longer time period migh  ...[more]

Similar Datasets

| S-EPMC2849086 | biostudies-literature
| S-EPMC9294578 | biostudies-literature
| S-EPMC7577434 | biostudies-literature
| S-EPMC7906864 | biostudies-literature
| S-EPMC11571314 | biostudies-literature
| S-EPMC7993591 | biostudies-literature
| S-EPMC10009542 | biostudies-literature
| S-EPMC7693057 | biostudies-literature
| S-EPMC10132050 | biostudies-literature
| S-EPMC3507567 | biostudies-literature