Unknown

Dataset Information

0

Effect of controlled sequential elevation timing of the head and thorax during cardiopulmonary resuscitation on cerebral perfusion pressures in a porcine model of cardiac arrest.


ABSTRACT:

Aim

Controlled sequential elevation of the head and thorax (CSE) during active compression-decompression (ACD) CPR with an impedance threshold device (ITD) augments cerebral (CerPP) and coronary (CorPP) perfusion pressures. The optimal CSE is unknown.

Methods

After 8 minutes of untreated VF, 40 kg anesthetized female pigs were positioned on a customized head and thorax elevation device (CED). After 2 min of automated ACD + ITD-16 CPR to 'prime the system', 12 pigs were randomized to CSE to the highest CED position over 4-min or 10-min. The primary outcome was CerPP after 7 minutes of CPR. Secondarily, 24-sec (without a priming step) and 2-min CSE times were similarly tested (n = 6 group) in a non-randomized order. Values expressed as mean ± SD.

Results

After 7 min of CPR, CerPPs were significantly higher in the 4-min vs 10-min CSE groups (53 ± 14.4 vs 38.5 ± 3.6 mmHg respectively, p = 0.03) whereas CorPP trended higher. The 4-min CSE group achieved 50% of baseline (50% BL) CerPP faster than the 10-min group (2.5 ± 1.2 vs 6 ± 3.1 minutes, p = 0.03). CerPP values in the 2-min and 4-min CSE groups were significantly higher than in the 24-sec group. With CSE, CerPPs and CorPPs increased over time in all groups.

Conclusions

By optimizing controlled sequential elevation timing, CerPP values achieved 50% of baseline within less than 2.5 minutes and >80% of baseline after 7 minutes of CPR. This novel CPR approach rapidly restored CerPPs to near normal values non-invasively and without vasopressors.

SUBMITTER: Rojas-Salvador C 

PROVIDER: S-EPMC9358682 | biostudies-literature | 2020 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Effect of controlled sequential elevation timing of the head and thorax during cardiopulmonary resuscitation on cerebral perfusion pressures in a porcine model of cardiac arrest.

Rojas-Salvador Carolina C   Moore Johanna C JC   Salverda Bayert B   Lick Michael M   Debaty Guillaume G   Lurie Keith G KG  

Resuscitation 20200121


<h4>Aim</h4>Controlled sequential elevation of the head and thorax (CSE) during active compression-decompression (ACD) CPR with an impedance threshold device (ITD) augments cerebral (CerPP) and coronary (CorPP) perfusion pressures. The optimal CSE is unknown.<h4>Methods</h4>After 8 minutes of untreated VF, 40 kg anesthetized female pigs were positioned on a customized head and thorax elevation device (CED). After 2 min of automated ACD + ITD-16 CPR to 'prime the system', 12 pigs were randomized  ...[more]

Similar Datasets

| S-EPMC7855054 | biostudies-literature
| S-EPMC10174369 | biostudies-literature
| S-EPMC7895327 | biostudies-literature
| S-EPMC9834834 | biostudies-literature
| S-EPMC10882798 | biostudies-literature
| S-EPMC6652040 | biostudies-literature
| S-EPMC6240573 | biostudies-literature
2010-06-05 | GSE22165 | GEO
| S-EPMC4866776 | biostudies-literature
| S-EPMC2737333 | biostudies-literature