Unknown

Dataset Information

0

Electrochemical Determination of 4-Bromophenoxyacetic Acid Based on CeO2/eGr Composite.


ABSTRACT: The determination of plant growth regulators is of great importance for the quality monitoring of crops. In this work, 4-bromophenoxyacetic acid (4-BPA), one of the phenoxyacetic acids, was detected via the electrochemical method for the first time. A CeO2-decorated electrochemical exfoliated graphene (eGr) composite (CeO2/eGr) was constructed as the sensor for sensitive detection of 4-BPA due to the synergistic effect of the excellent catalytic active sites of CeO2 and good electron transference of the eGr. The developed CeO2/eGr sensor displayed a good linearity in a wide range from 0.3 to 150 μmol/L and the lowest detection limit of 0.06 μmol/L for 4-BPA detection. Electrochemical oxidation of 4-BPA follows a mix-controlled process on the CeO2/eGr electrode, which involves 2e in the transference process. This developed CeO2/eGr sensor has excellent repeatability with a relative standard deviation (RSD) of 2.35% in 10 continuous measurements. Moreover, the practical application of the sensor for 4-BPA detection in apple juice has recoveries in the range of 90-108%. This proposed CeO2/eGr sensor has great potential for detecting plant growth regulators in the agricultural industry.

SUBMITTER: Du H 

PROVIDER: S-EPMC9496571 | biostudies-literature | 2022 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrochemical Determination of 4-Bromophenoxyacetic Acid Based on CeO<sub>2</sub>/eGr Composite.

Du Haijun H   Zhang Yan Y   Wang Xin X   Hu Huali H   Ai Jixing J   Zhou Huanxi H   Yan Xia X   Yang Yang Y   Lu Zhiwei Z  

Biosensors 20220915 9


The determination of plant growth regulators is of great importance for the quality monitoring of crops. In this work, 4-bromophenoxyacetic acid (4-BPA), one of the phenoxyacetic acids, was detected via the electrochemical method for the first time. A CeO<sub>2</sub>-decorated electrochemical exfoliated graphene (eGr) composite (CeO<sub>2</sub>/eGr) was constructed as the sensor for sensitive detection of 4-BPA due to the synergistic effect of the excellent catalytic active sites of CeO<sub>2</s  ...[more]

Similar Datasets

| S-EPMC10981725 | biostudies-literature
| S-EPMC9578399 | biostudies-literature
| S-EPMC9069452 | biostudies-literature
| S-EPMC9599135 | biostudies-literature
| S-EPMC9916758 | biostudies-literature
| S-EPMC10527261 | biostudies-literature
| S-EPMC9060248 | biostudies-literature
| S-EPMC10059818 | biostudies-literature
| S-EPMC11901975 | biostudies-literature
| S-EPMC11196949 | biostudies-literature