Cardiac resynchronization therapy (CRT) is an effective treatment for patients with heart failure; however, 30% of patients do not respond to the treatment. We sought to derive patient-specific left ventricle maps of lead placement scores (LPS) that highlight target pacing lead sites for achieving a higher probability of CRT response.Methods
Eighty-two subjects recruited for the ImagingCRT trial (Empiric Versus Imaging Guided Left Ventricular Lead Placement in Cardiac Resynchronization Therapy) were retrospectively analyzed. All 82 subjects had 2 contrast-enhanced full cardiac cycle 4-dimensional computed tomography scans: a baseline and a 6-month follow-up scan. CRT response was defined as a reduction in computed tomography-derived end-systolic volume ≥15%. Eight left ventricle features derived from the baseline scans were used to train a support vector machine via a bagging approach. An LPS map over the left ventricle was created for each subject as a linear combination of the support vector machine feature weights and the subject's own feature vector. Performance for distinguishing responders was performed on the original 82 subjects.Results
Fifty-two (63%) subjects were responders. Subjects with an LPS≤Q1 (lower-quartile) had a posttest probability of responding of 14% (3/21), while subjects with an LPS≥ Q3 (upper-quartile) had a posttest probability of responding of 90% (19/21). Subjects with Q1Conclusions
An LPS map was defined using 4-dimensional computed tomography-derived features of left ventricular mechanics. The LPS correlated with CRT response, reclassifying 25% of the subjects into low probability of response, 25% into high probability of response, and 50% unchanged. These encouraging results highlight the potential utility of 4-dimensional computed tomography in guiding patient selection for CRT. The present findings need verification in larger independent data sets and prospective trials.
SUBMITTER: Manohar A
PROVIDER: S-EPMC9558060 | biostudies-literature | 2022 Aug
REPOSITORIES: biostudies-literature
Circulation. Cardiovascular imaging 20220816 8
<h4>Background</h4>Cardiac resynchronization therapy (CRT) is an effective treatment for patients with heart failure; however, 30% of patients do not respond to the treatment. We sought to derive patient-specific left ventricle maps of lead placement scores (LPS) that highlight target pacing lead sites for achieving a higher probability of CRT response.<h4>Methods</h4>Eighty-two subjects recruited for the ImagingCRT trial (Empiric Versus Imaging Guided Left Ventricular Lead Placement in Cardiac ...[more]