Unknown

Dataset Information

0

Cardiac implantable device interrogation in left ventricular systolic dysfunction reveals physiologic abnormalities prior to symptom onset in COVID-19: a case series.


ABSTRACT:

Background

COVID-19 has affected individuals across the globe, and those with cardiac implantable electronic devices (CIEDs) likely represent a high-risk group. These devices can be interrogated to reveal information about the patient activity, heart rate parameters, and respiratory rate.

Case summary

Four patients with CIEDs and left ventricular dysfunction were admitted to a single institution for COVID-19 infection. Each patient survived hospitalization, and none required intensive care. Retrospectively, CIED interrogation revealed each patient had decreased activity level prior to their reporting COVID-19 symptoms. Similarly, respiratory rate increased before symptom onset for three of the patients, while one did not have these data available. Of the three patients with heart rate variability (HRV) available, two had decreased HRV before they developed symptoms. After hospital discharge, these parameters returned to their baseline.

Discussion

This case series suggests physiologic changes identifiable through interrogation of CIEDs may occur prior to the reported onset of COVID-19 symptoms. These data may provide objective evidence on which to base more sensitive assessments of infectious risk when performing contact tracing in communities.

SUBMITTER: Delfiner MS 

PROVIDER: S-EPMC9585899 | biostudies-literature | 2022 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cardiac implantable device interrogation in left ventricular systolic dysfunction reveals physiologic abnormalities prior to symptom onset in COVID-19: a case series.

Delfiner Matthew S MS   Bocchese Matthew M   Dalsania Raj R   Alhassani Zaineb Z   Keihl Joshua J   Vaidya Anjali A   Brisco-Bacik Meredith A MA   Whitman Isaac R IR  

European heart journal. Case reports 20221003 10


<h4>Background</h4>COVID-19 has affected individuals across the globe, and those with cardiac implantable electronic devices (CIEDs) likely represent a high-risk group. These devices can be interrogated to reveal information about the patient activity, heart rate parameters, and respiratory rate.<h4>Case summary</h4>Four patients with CIEDs and left ventricular dysfunction were admitted to a single institution for COVID-19 infection. Each patient survived hospitalization, and none required inten  ...[more]

Similar Datasets

| S-EPMC9349024 | biostudies-literature
| S-EPMC10770093 | biostudies-literature
| S-EPMC9205013 | biostudies-literature
| S-EPMC10927433 | biostudies-literature
| S-EPMC6064848 | biostudies-literature
| S-EPMC10500352 | biostudies-literature
| S-EPMC9300057 | biostudies-literature
| S-EPMC8853951 | biostudies-literature
| S-EPMC7893197 | biostudies-literature