Comparison and Harmonization of Different Semi-Automated and Automated qRT-PCR Assays in the Assessment of SARS-CoV-2.


ABSTRACT: In SARS-CoV-2 diagnostics, cycle threshold (Ct) values from qRT-PCRs semi-quantitatively estimate a patient's viral load. However, relevant analytical differences between qRT-PCR assays are often neglected. This study was designed (i) to identify such differences between five commonly used assays and (ii) to demonstrate a straightforward strategy to harmonize them. QRT-PCRs for SARS-CoV-2 were carried out in 85 oropharyngeal swab samples using three fully automated (Alinity m, cobas®6800 and GeneXpert) and two semi-automated (genesig® and RIDA®GENE) assays. Qualitative results (positive/negative) showed excellent comparability between the fully automated assays, but not between the Alinity m and semi-automated methods. Ct values significantly varied between all the methods, with the median values ranging from 22.76 (Alinity m) to 30.89 (RIDA®GENE) and 31.50 (genesig®), indicating the lowest sensitivity for semi-automated methods. Passing-Bablok analysis further revealed systemic biases. Assay-specific viral load concentration calculations-based on generated individual standard curves-resulted in much better comparability between the assays. Applying these calculations, significant differences were no longer detectable. This study highlights relevant analytical differences between SARS-CoV-2 qRT-PCR assays, leading to divergent decisions about the mandatory isolation of infected individuals. Secondly, we propose a strategy to harmonize qRT-PCR assays to achieve better comparability. Our findings are of particular interest for laboratories utilizing different assays.

SUBMITTER: Dierks S 

PROVIDER: S-EPMC9610219 | biostudies-literature | 2022 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison and Harmonization of Different Semi-Automated and Automated qRT-PCR Assays in the Assessment of SARS-CoV-2.

Dierks Sascha S   Thiele Karin K   Bohne Wolfgang W   Lugert Raimond R   Weig Michael M   Groß Uwe U   von Ahsen Nicolas N   Schanz Julie J   Fischer Andreas A   Schnelle Moritz M  

Viruses 20221012 10


In SARS-CoV-2 diagnostics, cycle threshold (Ct) values from qRT-PCRs semi-quantitatively estimate a patient's viral load. However, relevant analytical differences between qRT-PCR assays are often neglected. This study was designed (i) to identify such differences between five commonly used assays and (ii) to demonstrate a straightforward strategy to harmonize them. QRT-PCRs for SARS-CoV-2 were carried out in 85 oropharyngeal swab samples using three fully automated (Alinity m, cobas<sup>®</sup>6  ...[more]

Similar Datasets

| S-EPMC7396207 | biostudies-literature
| S-EPMC7559084 | biostudies-literature
| S-EPMC9406901 | biostudies-literature
| S-EPMC10547753 | biostudies-literature
| S-EPMC9769721 | biostudies-literature
| S-EPMC7706421 | biostudies-literature
| S-EPMC7315722 | biostudies-literature
| S-EPMC7833356 | biostudies-literature
| S-EPMC2881921 | biostudies-literature
| S-EPMC7278635 | biostudies-literature