Unknown

Dataset Information

0

Development and Clinical Validation of RT-LAMP-Based Lateral-Flow Devices and Electrochemical Sensor for Detecting Multigene Targets in SARS-CoV-2.


ABSTRACT: Consistently emerging variants and the life-threatening consequences of SARS-CoV-2 have prompted worldwide concern about human health, necessitating rapid and accurate point-of-care diagnostics to limit the spread of COVID-19. Still, However, the availability of such diagnostics for COVID-19 remains a major rate-limiting factor in containing the outbreaks. Apart from the conventional reverse transcription polymerase chain reaction, loop-mediated isothermal amplification-based (LAMP) assays have emerged as rapid and efficient systems to detect COVID-19. The present study aims to develop RT-LAMP-based assay system for detecting multiple targets in N, ORF1ab, E, and S genes of the SARS-CoV-2 genome, where the end-products were quantified using spectrophotometry, paper-based lateral-flow devices, and electrochemical sensors. The spectrophotometric method shows a LOD of 10 agµL-1 for N, ORF1ab, E genes and 100 agµL-1 for S gene in SARS-CoV-2. The developed lateral-flow devices showed an LOD of 10 agµL-1 for all four gene targets in SARS-CoV-2. An electrochemical sensor developed for N-gene showed an LOD and E-strip sensitivity of log 1.79 ± 0.427 pgµL-1 and log 0.067 µA/pg µL-1/mm2, respectively. The developed assay systems were validated with the clinical samples from COVID-19 outbreaks in 2020 and 2021. This multigene target approach can effectively detect emerging COVID-19 variants using combination of various analytical techniques at testing facilities and in point-of-care settings.

SUBMITTER: Saxena A 

PROVIDER: S-EPMC9658514 | biostudies-literature | 2022 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development and Clinical Validation of RT-LAMP-Based Lateral-Flow Devices and Electrochemical Sensor for Detecting Multigene Targets in SARS-CoV-2.

Saxena Apoorva A   Rai Pawankumar P   Mehrotra Srishti S   Baby Samiya S   Singh Suman S   Srivastava Vikas V   Priya Smriti S   Sharma Sandeep K SK  

International journal of molecular sciences 20221028 21


Consistently emerging variants and the life-threatening consequences of SARS-CoV-2 have prompted worldwide concern about human health, necessitating rapid and accurate point-of-care diagnostics to limit the spread of COVID-19. Still, However, the availability of such diagnostics for COVID-19 remains a major rate-limiting factor in containing the outbreaks. Apart from the conventional reverse transcription polymerase chain reaction, loop-mediated isothermal amplification-based (LAMP) assays have  ...[more]

Similar Datasets

| S-EPMC10949940 | biostudies-literature
| S-EPMC8931854 | biostudies-literature
| S-EPMC5220095 | biostudies-literature
| S-EPMC7081253 | biostudies-literature
| S-EPMC6353813 | biostudies-literature
| S-EPMC9261132 | biostudies-literature
| S-EPMC11438901 | biostudies-literature
| S-EPMC10077809 | biostudies-literature
| S-EPMC8645337 | biostudies-literature
| S-EPMC8758200 | biostudies-literature