Ontology highlight
ABSTRACT: Introduction
Real-time continuous glucose monitoring (rt-CGM) involves the measurement and display of glucose concentrations, potentially improving glucose control among insulin-treated patients with type 2 diabetes (T2D). The present analysis aimed to conduct a cost-effectiveness analysis of rt-CGM versus self-monitoring of blood glucose (SMBG) based on a USA retrospective cohort study in insulin-treated people with T2D adapted to the UK.Methods
Long-term costs and clinical outcomes were estimated using the CORE Diabetes Model, with clinical input data sourced from a retrospective cohort study. Patients were assumed to have a baseline glycated hemoglobin (HbA1c) of 8.3%. Patients using rt-CGM were assumed to have a 0.56% reduction in HbA1c based on the mean difference between groups after 12 months of follow-up. Reduced fingerstick testing when using rt-CGM was associated with a quality of life (QoL) benefit. The analysis was performed over a lifetime time horizon from a National Health Service (NHS) perspective, including only direct costs from published data. Future costs and clinical outcomes were discounted at 3.5% per annum. Extensive sensitivity analyses were performed.Results
Projections showed that rt-CGM was associated with increased quality-adjusted life expectancy of 0.731 quality-adjusted life years (QALYs) and increased mean total lifetime costs of Great British pounds (GBP) 2694, and an incremental cost-effectiveness ratio of GBP 3684 per QALY compared with SMBG. Key drivers of outcomes included HbA1c reduction and reduced fingerstick testing QoL benefit.Conclusions
Over patient lifetimes, rt-CGM was associated with improved clinical outcomes and is highly likely to be cost effective versus SMBG in people with T2D on insulin therapy in the UK.
SUBMITTER: Isitt JJ
PROVIDER: S-EPMC9663778 | biostudies-literature | 2022 Dec
REPOSITORIES: biostudies-literature
Isitt John J JJ Roze Stéphane S Sharland Helen H Cogswell Greg G Alshannaq Hamza H Norman Gregory J GJ Lynch Peter M PM
Diabetes therapy : research, treatment and education of diabetes and related disorders 20221019 11-12
<h4>Introduction</h4>Real-time continuous glucose monitoring (rt-CGM) involves the measurement and display of glucose concentrations, potentially improving glucose control among insulin-treated patients with type 2 diabetes (T2D). The present analysis aimed to conduct a cost-effectiveness analysis of rt-CGM versus self-monitoring of blood glucose (SMBG) based on a USA retrospective cohort study in insulin-treated people with T2D adapted to the UK.<h4>Methods</h4>Long-term costs and clinical outc ...[more]