Unknown

Dataset Information

0

Rapid and Sensitive Detection of Hepatitis C Virus in Clinical Blood Samples Using Reverse Transcriptase Polymerase Spiral Reaction.


ABSTRACT: This study established a new polymerase spiral reaction (PSR) that combines with reverse transcription reactions for HCV detection targeting 5'UTR gene. To avoid cross-contamination of aerosols, an isothermal amplification tube (IAT), as a separate containment control, was used to judge the result. After optimizing the RT-PSR reaction system, its effectiveness and specificity were tested against 15 different virus strains which included 8 that were HCV positive and 7 as non-HCV controls. The results showed that the RT-PSR assay effectively detected all 8 HCV strains, and no false positives were found among the 7 non-HCV strains. The detection limit of our RT-PSR assay is comparable to the real-time RT-PCR, but is more sensitive than the RT-LAMP. The established RT-PSR assay was further evaluated for detection of HCV in clinical blood samples, and the resulting 80.25% detection rate demonstrated better or similar effectiveness compared to the RT-LAMP (79.63%) and real-time RT-PCR (80.25%). Overall, the results showed that the RT-PSR assay offers high specificity and sensitivity for HCV detection with great potential for screening HCV in clinical blood samples.

SUBMITTER: Sun W 

PROVIDER: S-EPMC9728396 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Rapid and Sensitive Detection of Hepatitis C Virus in Clinical Blood Samples Using Reverse Transcriptase Polymerase Spiral Reaction.

Sun Wenying W   Du Ying Y   Li Xingku X   Du Bo B  

Journal of microbiology and biotechnology 20200301 3


This study established a new polymerase spiral reaction (PSR) that combines with reverse transcription reactions for HCV detection targeting 5'UTR gene. To avoid cross-contamination of aerosols, an isothermal amplification tube (IAT), as a separate containment control, was used to judge the result. After optimizing the RT-PSR reaction system, its effectiveness and specificity were tested against 15 different virus strains which included 8 that were HCV positive and 7 as non-HCV controls. The res  ...[more]

Similar Datasets

| S-EPMC9750508 | biostudies-literature
| S-EPMC4905949 | biostudies-literature
| S-EPMC7818967 | biostudies-literature
| S-EPMC7492713 | biostudies-literature
| S-EPMC5544097 | biostudies-literature
| S-EPMC7126732 | biostudies-literature
| S-EPMC4172905 | biostudies-literature
| S-EPMC4909037 | biostudies-literature
| S-EPMC7218033 | biostudies-literature
| S-EPMC7112770 | biostudies-literature