ABSTRACT: Background
This study investigated accuracy and consistency of epicardial adipose tissue (EAT) quantification in non-ECG-gated chest computed tomography (CT) scans.Methods
EAT volume was semi-automatically quantified using a standard Hounsfield unit threshold (- 190, - 30) in three independent cohorts: (1) Cohort 1 (N = 49): paired 120 kVp ECG-gated cardiac non-contrast CT (NCCT) and 120 kVp non-ECG-gated chest NCCT; (2) Cohort 2 (N = 34): paired 120 kVp cardiac NCCT and 100 kVp non-ECG-gated chest NCCT; (3) Cohort 3 (N = 32): paired non-ECG-gated chest NCCT and chest contrast-enhanced CT (CECT) datasets (including arterial phase and venous phase). Images were reconstructed with the slice thicknesses of 1.25 mm and 5 mm in the chest CT datasets, and 3 mm in the cardiac NCCT