Sources of Variability in Real-time Monitoring Data for Fine Particulate Matter: Comparability of Three Wearable Monitors in an Urban Setting.
Ontology highlight
ABSTRACT: The increasing availability of portable air pollution monitoring devices has greatly enhanced the ability to measure personal exposures in real time. However, these devices vary considerably in their cost and specifications, and questions remain as to their reliability and practicality for use in epidemiological investigations. In this field study, three personal PM2.5 exposure monitors (two nephelometers, one optical particle counter) were compared in an urban setting to assess their feasibility for use in future studies. In total, 3963 1-min measurements were collected over 12 days from locations of several types (e.g., above and below-ground subway stations, sidewalks next to urban traffic, outdoor construction sites) in the Washington, D.C. metropolitan area. Overall, we obs
SUBMITTER: Fisher JA
PROVIDER: S-EPMC9815482 | biostudies-literature | 2019 Apr
REPOSITORIES: biostudies-literature