Unknown

Dataset Information

0

Diagnostic Accuracy of a Convolutional Neural Network Assessment of Solitary Pulmonary Nodules Compared With PET With CT Imaging and Dynamic Contrast-Enhanced CT Imaging Using Unenhanced and Contrast-Enhanced CT Imaging.


ABSTRACT:

Background

Solitary pulmonary nodules (SPNs) measuring 8 to 30 mm in diameter require further workup to determine the likelihood of malignancy.

Research question

What is the diagnostic performance of a lung cancer prediction convolutional neural network (LCP-CNN) in SPNs using unenhanced and contrast-enhanced CT imaging compared with the current clinical workup?

Study design and methods

This was a post hoc analysis of the Single Pulmonary Nodule Investigation: Accuracy and Cost-Effectiveness of Dynamic Contrast Enhanced Computed Tomography in the Characterisation of Solitary Pulmonary Nodules trial, a prospective multicenter study comparing the diagnostic accuracy of dynamic contrast-enhanced (DCE) CT imaging with PET imaging in SPNs. The LCP-CNN was designed and validated in an external cohort. LCP-CNN-generated risk scores were created from the noncontrast and contrast-enhanced CT scan images from the DCE CT imaging. The gold standard was histologic analysis or 2 years of follow-up. The area under the receiver operating characteristic curves (AUC) were calculated using LCP-CNN score, maximum standardized uptake value, and DCE CT scan maximum enhancement and were compared using the DeLong test.

Results

Two hundred seventy participants (mean ± SD age, 68.3 ± 8.8 years; 49% women) underwent PET with CT scan imaging and DCE CT imaging with CT scan data available centrally for LCP-CNN analysis. The accuracy of the LCP-CNN on the noncontrast images (AUC, 0.83; 95% CI, 0.79-0.88) was superior to that of DCE CT imaging (AUC, 0.76; 95% CI, 0.69-0.82; P = .03) and equal to that of PET with CT scan imaging (AUC, 0.86; 95% CI, 0.81-0.90; P = .35). The presence of contrast resulted in a small reduction in diagnostic accuracy, with the AUC falling from 0.83 (95% CI, 0.79-0.88) on the noncontrast images to 0.80 to 0.83 after contrast (P < .05 for 240 s after contrast only).

Interpretation

An LCP-CNN algorithm provides an AUC equivalent to PET with CT scan imaging in the diagnosis of solitary pulmonary nodules.

Trial registration

ClinicalTrials.gov Identifier; No.: NCT02013063.

SUBMITTER: Weir-McCall JR 

PROVIDER: S-EPMC9899635 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diagnostic Accuracy of a Convolutional Neural Network Assessment of Solitary Pulmonary Nodules Compared With PET With CT Imaging and Dynamic Contrast-Enhanced CT Imaging Using Unenhanced and Contrast-Enhanced CT Imaging.

Weir-McCall Jonathan R JR   Debruyn Elise E   Harris Scott S   Qureshi Nagmi R NR   Rintoul Robert C RC   Gleeson Fergus V FV   Gilbert Fiona J FJ  

Chest 20220908 2


<h4>Background</h4>Solitary pulmonary nodules (SPNs) measuring 8 to 30 mm in diameter require further workup to determine the likelihood of malignancy.<h4>Research question</h4>What is the diagnostic performance of a lung cancer prediction convolutional neural network (LCP-CNN) in SPNs using unenhanced and contrast-enhanced CT imaging compared with the current clinical workup?<h4>Study design and methods</h4>This was a post hoc analysis of the Single Pulmonary Nodule Investigation: Accuracy and  ...[more]

Similar Datasets

| S-EPMC11412969 | biostudies-literature
| S-EPMC8584460 | biostudies-literature
| S-EPMC9362916 | biostudies-literature
| S-EPMC4482532 | biostudies-literature
| S-EPMC6579038 | biostudies-literature
| S-EPMC3353415 | biostudies-literature
| S-EPMC4739615 | biostudies-literature
| S-EPMC7964583 | biostudies-literature
| S-EPMC5300187 | biostudies-literature
| S-EPMC11833577 | biostudies-literature