Unknown

Dataset Information

0

A novel and practical method to add video monitoring to tilt table testing.


ABSTRACT:

Aims

We describe a novel, practical, and inexpensive method to add video recording during tilt table testing (TTT): Open-Access-Video-TTT.

Methods and results

The Open-Access-Video-TTT set-up uses a personal computer (PC) to capture screen video data from a non-invasive-beat-to-beat (NIBTB) haemodynamic blood pressure (BP) device, combined with video recording of a patient, using Open Broadcaster Software (OBS®). The new Open-Access-Video-TTT set up was tested with both the Finometer (model Finapres Nova®, Medical Systems, the Netherlands) and the Task Force® Touch Cardio monitor (CNSystems, Austria). For this, the Finapres Nova® was enabled in 'remote' mode and Real Video Network Computing (RealVNC®) was installed on the PC/laptop. The Task Force® has a DisplayPort (DP) port, for which a DP/ high-definition multimedia interface (HDMI) cable and a video capture card is used to merge the signals to the PC/laptop. With this method the combined images are stored as a new video signal. TTT can be performed with any routine protocol.

Conclusions

Open Access-Video-TTT worked well for both the Finapres NOVA® and the Task Force Monitor ®. This novel method can be used easily by all physicians who wish to add video recording during TTT who do not have access to an electroencephalogram machine.

SUBMITTER: de Lange FJ 

PROVIDER: S-EPMC9935048 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

A novel and practical method to add video monitoring to tilt table testing.

de Lange Frederik Jorrit FJ   Hofland Willem Petrus Merijn Emmanuël WPME   Ferrara Alessio A   Gargaro Alessio A   Brignole Michele M   van Dijk Jan Gerrit JG  

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 20230201 2


<h4>Aims</h4>We describe a novel, practical, and inexpensive method to add video recording during tilt table testing (TTT): Open-Access-Video-TTT.<h4>Methods and results</h4>The Open-Access-Video-TTT set-up uses a personal computer (PC) to capture screen video data from a non-invasive-beat-to-beat (NIBTB) haemodynamic blood pressure (BP) device, combined with video recording of a patient, using Open Broadcaster Software (OBS®). The new Open-Access-Video-TTT set up was tested with both the Finome  ...[more]

Similar Datasets

| S-EPMC4822062 | biostudies-other
| S-EPMC7807517 | biostudies-literature
| S-EPMC6133915 | biostudies-literature
| S-EPMC6704101 | biostudies-literature
| S-EPMC4666666 | biostudies-literature
| S-EPMC10238463 | biostudies-literature
| S-EPMC7141961 | biostudies-literature
| S-EPMC2633421 | biostudies-literature
| S-EPMC8422105 | biostudies-literature
| S-EPMC3767008 | biostudies-literature