The utility and advantages of the recently introduced two-dimensional quadrupole ion trap mass spectrometer in proteomics over the traditional three-dimensional ion trap mass spectrometer have not been systematically characterized. Here we rigorously compared the performance of these two platforms b...
Since its introduction a few years ago, the linear ion trap Orbitrap (LTQ Orbitrap) instrument has become a powerful tool in proteomics research. For high resolution mass spectrometry measurements ions are accumulated in the linear ion trap and passed on to the Orbitrap analyzer. Simultaneously with...
A combined electrodynamic ion funnel and ion trap coupled to an orthogonal acceleration (oa)-time-of-flight mass spectrometer was developed and characterized. The ion trap was incorporated through the use of added terminal electrodynamic ion funnel electrodes enabling control over the axial dc gradi...
A miniature, planar, differential ion mobility spectrometer (DMS) was interfaced to an LCQ classic ion trap to conduct selective ion filtration prior to mass analysis in order to extend the dynamic range of the trap. Space charge effects are known to limit the functional ion storage capacity of ion ...
Ion mobility instruments that utilize nitrogen as buffer gas are often preceded by an ion trap and accumulation region that also uses nitrogen, and for different inert gases, no significant effects upon performance are expected for ion mobility spectrometry (IMS) of larger ions. However, we have obs...
A new instrument that couples a low-pressure drift tube with a linear ion trap mass spectrometer is demonstrated for complex mixture analysis. The combination of the low-pressure separation with the ion trapping capabilities provides several benefits for complex mixture analysis. These include high ...
Single-frequency ion parking, a useful technique in electrospray mass spectrometry (ESI-MS), involves gas-phase charge-reduction ion/ion reactions in an electrodynamic ion trap in conjunction with the application of a supplementary oscillatory voltage to selectively inhibit the reaction rate of an i...
Proteomic workflows have traditionally been divided into discovery-based and targeted approaches with instrumentation optimized specifically for each. Discovery experiments typically utilize high-resolution analyzers, while targeted workflows rely on the sensitivity and specificity of triple quadrup...
A novel dual cell linear ion trap Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) and its performance characteristics are reported. A linear ion trap-Fourier transform ion cyclotron resonance mass spectrometer has been modified to incorporate a LTQ-Velos mass spectrometer. Th...
We demonstrate operation of the first cryogenic 2D linear ion trap (LIT) with mass-selective capabilities. This trap presents a number of advantages for infrared ion "action" spectroscopy studies, particularly those employing the "tagging/messenger" spectroscopy approach. The high trapping efficienc...