Unknown

Dataset Information

Characterizing the effects of structural fires on fine particulate matter with a dense sensing network.


ABSTRACT: Short-term increases in air pollution levels are linked to large adverse effects on health and productivity. However, existing regulatory monitoring systems lack the spatial or temporal resolution needed to capture localized events. This study uses a dense network of over 100 sensors, deployed across the city of Chicago, Illinois, to capture the spread of smoke from short-term structural fire events. Examining all large structural fires that occurred in the city over a year (N = 21), we characterize differences in PM[Formula: see text] concentrations downwind versus upwind of the fires. On average, we observed increases of up to 10.7 [Formula: see text]g/m[Formula: see text] (95% CI 5.7-15.7) for sensors within 2 km and up to 7.7 [Formula: see text]g/m[Formula: see text] (95% CI 3.4-12.0)

SUBMITTER: Anyachebelu A 

PROVIDER: S-EPMC10409864 | biostudies-literature | 2023 Aug

REPOSITORIES: biostudies-literature