Unknown

Dataset Information

0

Brain Re-Irradiation Robustly Accounting for Previously Delivered Dose.


ABSTRACT: (1) Background: The STRIDeR (Support Tool for Re-Irradiation Decisions guided by Radiobiology) planning pathway aims to facilitate anatomically appropriate and radiobiologically meaningful re-irradiation (reRT). This work evaluated the STRIDeR pathway for robustness compared to a more conservative manual pathway. (2) Methods: For ten high-grade glioma reRT patient cases, uncertainties were applied and cumulative doses re-summed. Geometric uncertainties of 3, 6 and 9 mm were applied to the background dose, and LQ model robustness was tested using α/β variations (values 1, 2 and 5 Gy) and the linear quadratic linear (LQL) model δ variations (values 0.1 and 0.2). STRIDeR robust optimised plans, incorporating the geometric and α/β uncertainties during optimisation, were also generated. (3) Results: The STRIDeR and manual pathways both achieved clinically acceptable plans in 8/10 cases but with statistically significant improvements in the PTV D98% (p < 0.01) for STRIDeR. Geometric and LQ robustness tests showed comparable robustness within both pathways. STRIDeR plans generated to incorporate uncertainties during optimisation resulted in a superior plan robustness with a minimal impact on PTV dose benefits. (4) Conclusions: Our results indicate that STRIDeR pathway plans achieved a similar robustness to manual pathways with improved PTV doses. Geometric and LQ model uncertainties can be incorporated into the STRIDeR pathway to facilitate robust optimisation.

SUBMITTER: Thompson C 

PROVIDER: S-EPMC10417278 | biostudies-literature | 2023 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications


(1) Background: The STRIDeR (Support Tool for Re-Irradiation Decisions guided by Radiobiology) planning pathway aims to facilitate anatomically appropriate and radiobiologically meaningful re-irradiation (reRT). This work evaluated the STRIDeR pathway for robustness compared to a more conservative manual pathway. (2) Methods: For ten high-grade glioma reRT patient cases, uncertainties were applied and cumulative doses re-summed. Geometric uncertainties of 3, 6 and 9 mm were applied to the backgr  ...[more]

Similar Datasets

| S-EPMC9476990 | biostudies-literature
| S-EPMC9913463 | biostudies-literature
| S-EPMC4730145 | biostudies-literature
| S-EPMC7164259 | biostudies-literature
| S-EPMC5707405 | biostudies-literature
| S-EPMC8316636 | biostudies-literature
2004-06-17 | GSE1366 | GEO
| S-EPMC6422429 | biostudies-literature
| S-EPMC4741508 | biostudies-literature
| S-EPMC5022796 | biostudies-other