Unknown

Dataset Information

0

Simple Protein Analysis by Droplet Paper Spray Ionization Mass Spectrometry with Polyolefin Silica-Based Paper.


ABSTRACT: Paper spray ionization mass spectrometry (PSI MS) has emerged as a notable method for the rapid analysis of biological samples. However, the typical cellulose-based paper tip is incompatible with protein detection due to the strong interaction between cellulose hydroxyl groups and proteins. In this study, we utilized a commercially available polyolefin-based synthetic paper, Teslin®, as an alternative PSI substrate for simple protein analysis. We have named this method "droplet PSI" MS, as the aqueous protein solution droplet retains its shape on the Teslin® paper tip. For droplet PSI, no further chemical pretreatment was necessary for the Teslin® substrate; the only required preparation was shaping the Teslin® paper into a triangular tip. In droplet PSI MS, protein ion signals were instantly detected from a protein solution droplet upon applying a spray solvent in situ along with high voltage (HV). When compared with conventional PSI MS, our method demonstrated superior sensitivity. The droplet PSI MS utilizing Teslin® also showcased flexibility in real-time observation of protein alterations induced by an acid additive. Additionally, the effects of spray solvent composition and the application method were discussed.

SUBMITTER: An SJ 

PROVIDER: S-EPMC10647424 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Simple Protein Analysis by Droplet Paper Spray Ionization Mass Spectrometry with Polyolefin Silica-Based Paper.

An Sung Jun SJ   Kal Youngjoo Y   Jeong Minjoo M   Kang Sumin S   Kwak Byeongho B   Kim Hyunsoo H   Ryu Shihyeon S   Cha Sangwon S  

Molecules (Basel, Switzerland) 20231030 21


Paper spray ionization mass spectrometry (PSI MS) has emerged as a notable method for the rapid analysis of biological samples. However, the typical cellulose-based paper tip is incompatible with protein detection due to the strong interaction between cellulose hydroxyl groups and proteins. In this study, we utilized a commercially available polyolefin-based synthetic paper, Teslin<sup>®</sup>, as an alternative PSI substrate for simple protein analysis. We have named this method "droplet PSI" M  ...[more]

Similar Datasets

| S-EPMC8151837 | biostudies-literature
| S-EPMC6537876 | biostudies-literature
| S-EPMC9395369 | biostudies-literature
| S-EPMC6635430 | biostudies-literature
| S-EPMC11434060 | biostudies-literature
| S-EPMC9516698 | biostudies-literature
| S-EPMC11834250 | biostudies-literature
| S-EPMC3039116 | biostudies-literature
| S-EPMC3732448 | biostudies-literature
| S-EPMC10033633 | biostudies-literature