Comparison of the medium cutoff dialyzer and postdilution hemodiafiltration on the removal of small and middle molecule uremic toxins.


ABSTRACT:

Background

The medium cutoff (MCO) dialyzer increases the removal of several middle molecules more effectively than high-flux hemodialysis (HD). However, comparative data addressing the efficacy and safety of MCO dialyzers vs. postdilution hemodiafiltration (HDF) in Korean patients are lacking.

Methods

Nine patients with chronic HD were included in this pre-post study. Patients underwent HD with an MCO dialyzer for 4 weeks, followed by a 2-week washout period using a high-flux dialyzer to minimize carryover effects, and then turned over to postdilution HDF for 4 weeks. Reduction ratios and differences in the uremic toxins before and after dialysis were calculated from the MCO dialysis, postdilution HDF, and high-flux HD. In the in vitro study, EA.hy926 cells were incubated w