Validation of a Deep Learning Algorithm for Continuous, Real-Time Detection of Atrial Fibrillation Using a Wrist-Worn Device in an Ambulatory Environment.


ABSTRACT:

Background

Wearable devices may be useful for identification, quantification and characterization, and management of atrial fibrillation (AF). To date, consumer wrist-worn devices for AF detection using photoplethysmography-based algorithms perform only periodic checks when the user is stationary and are US Food and Drug Administration cleared for prediagnostic uses without intended use for clinical decision-making. There is an unmet need for medical-grade diagnostic wrist-worn devices that provide long-term, continuous AF monitoring.

Methods and results

We evaluated the performance of a wrist-worn device with lead-I ECG and continuous photoplethysmography (Verily Study Watch) and photoplethysmography-based convolutional neural network for AF detection and burden estimation in a prospective multicenter study that enrolled 117 patients with paroxysmal AF. A 14-day continuous ECG monitor (Zio XT) served as the reference device to evaluate algorithm sensitivity and specificity for detection of AF in 15-minute intervals. A total of 91 857 intervals were contributed by 111 subjects with evaluable reference and test data (18.3 h/d median watch wear time). The watch was 96.1% sensitive (95% CI, 92.7%-98.0%) and 98.1% specific (95% CI, 97.2%-99.1%) for interval-level AF detection. Photoplethysmography-derived AF burden estimation was highly correlated with the reference device burden (R2=0.986) with a mean difference of 0.8% (95% limits of agreement, -6.6% to 8.2%).

Conclusions

Continuous monitoring using a photoplethysmography-based convolutional neural network incorporated in a wrist-worn device has clinical-grade performance for AF detection and burden estimation. These findings suggest that monitoring can be performed with wrist-worn wearables for diagnosis and clinical management of AF.

Registration information

URL: https://www.clinicaltrials.gov; Unique identifier: NCT04546763.

SUBMITTER: Poh MZ 

PROVIDER: S-EPMC10727259 | biostudies-literature | 2023 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Validation of a Deep Learning Algorithm for Continuous, Real-Time Detection of Atrial Fibrillation Using a Wrist-Worn Device in an Ambulatory Environment.

Poh Ming-Zher MZ   Battisti Anthony J AJ   Cheng Li-Fang LF   Lin Janice J   Patwardhan Anil A   Venkataraman Ganesh S GS   Athill Charles A CA   Patel Nimesh S NS   Patel Chinmay P CP   Machado Christian E CE   Ellis Jeffrey T JT   Crosson Lori A LA   Tamura Yuriko Y   Plowman R Scooter RS   Turakhia Mintu P MP   Ghanbari Hamid H  

Journal of the American Heart Association 20230926 19


<h4>Background</h4>Wearable devices may be useful for identification, quantification and characterization, and management of atrial fibrillation (AF). To date, consumer wrist-worn devices for AF detection using photoplethysmography-based algorithms perform only periodic checks when the user is stationary and are US Food and Drug Administration cleared for prediagnostic uses without intended use for clinical decision-making. There is an unmet need for medical-grade diagnostic wrist-worn devices t  ...[more]

Similar Datasets

| S-EPMC11637493 | biostudies-literature
| S-EPMC9949528 | biostudies-literature
| S-EPMC8890076 | biostudies-literature
| S-EPMC10288196 | biostudies-literature
| S-EPMC6201454 | biostudies-literature
| S-EPMC6931792 | biostudies-literature
| S-EPMC6962225 | biostudies-literature
| S-EPMC8678736 | biostudies-literature
| S-EPMC7955365 | biostudies-literature
| S-EPMC9920931 | biostudies-literature