Project description:IntroductionVentricular perforation during radiofrequency ablation of ventricular tachycardia is a recognized serious complication that carries high morbidity and mortality. Perforation is often associated with local intramyocardial injury due to excess heat induced by catheter, 'steam pop'. The complication usually requires emergency surgical repair.Case presentationWe present a case, when the catheter found its way into the epicardium during left ventricular (LV) electroanatomic mapping without any serious complication. Angiography through the ablation catheter confirmed the diagnosis of LV coronary sinus fistula.DiscussionContrast injection through the irrigation port of the ablation catheter is a useful way of delineating anatomical anomalies during electrophysiology procedure.
Project description:BACKGROUND:Recent advances have enabled noninvasive mapping of cardiac arrhythmias with electrocardiographic imaging and noninvasive delivery of precise ablative radiation with stereotactic body radiation therapy (SBRT). We combined these techniques to perform catheter-free, electrophysiology-guided, noninvasive cardiac radioablation for ventricular tachycardia. METHODS:We targeted arrhythmogenic scar regions by combining anatomical imaging with noninvasive electrocardiographic imaging during ventricular tachycardia that was induced by means of an implantable cardioverter-defibrillator (ICD). SBRT simulation, planning, and treatments were performed with the use of standard techniques. Patients were treated with a single fraction of 25 Gy while awake. Efficacy was assessed by counting episodes of ventricular tachycardia, as recorded by ICDs. Safety was assessed by means of serial cardiac and thoracic imaging. RESULTS:From April through November 2015, five patients with high-risk, refractory ventricular tachycardia underwent treatment. The mean noninvasive ablation time was 14 minutes (range, 11 to 18). During the 3 months before treatment, the patients had a combined history of 6577 episodes of ventricular tachycardia. During a 6-week postablation "blanking period" (when arrhythmias may occur owing to postablation inflammation), there were 680 episodes of ventricular tachycardia. After the 6-week blanking period, there were 4 episodes of ventricular tachycardia over the next 46 patient-months, for a reduction from baseline of 99.9%. A reduction in episodes of ventricular tachycardia occurred in all five patients. The mean left ventricular ejection fraction did not decrease with treatment. At 3 months, adjacent lung showed opacities consistent with mild inflammatory changes, which had resolved by 1 year. CONCLUSIONS:In five patients with refractory ventricular tachycardia, noninvasive treatment with electrophysiology-guided cardiac radioablation markedly reduced the burden of ventricular tachycardia. (Funded by Barnes-Jewish Hospital Foundation and others.).
Project description:Ventricular tachycardia is a common and lethal complication after myocardial infarction. Here we show that focal transfer of a gene encoding a dominant-negative version of the KCNH2 potassium channel (KCNH2-G628S) to the infarct scar border eliminated all ventricular arrhythmias in a porcine model. No proarrhythmia or other negative effects were discernable. Our results demonstrate the potential viability of gene therapy for ablation of ventricular arrhythmias.
Project description:BackgroundData on relative safety, efficacy, and role of different percutaneous left ventricular assist devices for hemodynamic support during the ventricular tachycardia (VT) ablation procedure are limited.Methods and resultsWe performed a multicenter, observational study from a prospective registry including all consecutive patients (N=66) undergoing VT ablation with a percutaneous left ventricular assist devices in 6 centers in the United States. Patients with intra-aortic balloon pump (IABP group; N=22) were compared with patients with either an Impella or a TandemHeart device (non-IABP group; N=44). There were no significant differences in the baseline characteristics between both the groups. In non-IABP group (1) more patients could undergo entrainment/activation mapping (82% versus 59%; P=0.046), (2) more number of unstable VTs could be mapped and ablated per patient (1.05±0.78 versus 0.32±0.48; P<0.001), (3) more number of VTs could be terminated by ablation (1.59±1.0 versus 0.91±0.81; P=0.007), and (4) fewer VTs were terminated with rescue shocks (1.9±2.2 versus 3.0±1.5; P=0.049) when compared with IABP group. Complications of the procedure trended to be more in the non-IABP group when compared with those in the IABP group (32% versus 14%; P=0.143). Intermediate term outcomes (mortality and VT recurrence) during 12±5-month follow-up were not different between both groups. Left ventricular ejection fraction ≤15% was a strong and independent predictor of in-hospital mortality (53% versus 4%; P<0.001).ConclusionsImpella and TandemHeart use in VT ablation facilitates extensive activation mapping of several unstable VTs and requires fewer rescue shocks during the procedure when compared with using IABP.
Project description:ObjectivesThis study sought to characterize ventricular tachycardia (VT) ablation outcomes across nonischemic cardiomyopathy (NICM) etiologies and adjust these outcomes by patient-related comorbidities that could explain differences in arrhythmia recurrence rates.BackgroundOutcomes of catheter ablation of VT in patients with NICM could be related to etiology of NICM.MethodsData from 2,075 patients with structural heart disease referred for catheter ablation of VT from 12 international centers was retrospectively analyzed. Patient characteristics and outcomes were noted for the 6 most common NICM etiologies. Multivariable Cox proportional hazards modeling was used to adjust for potential confounders.ResultsOf 780 NICM patients (57 ± 14 years of age, 18% women, left ventricular ejection fraction 37 ± 13%), underlying prevalence was 66% for dilated idiopathic cardiomyopathy (DICM), 13% for arrhythmogenic right ventricular cardiomyopathy (ARVC), 6% for valvular cardiomyopathy, 6% for myocarditis, 4% for hypertrophic cardiomyopathy, and 3% for sarcoidosis. One-year freedom from VT was 69%, and freedom from VT, heart transplantation, and death was 62%. On unadjusted competing risk analysis, VT ablation in ARVC demonstrated superior VT-free survival (82%) versus DICM (p ≤ 0.01). Valvular cardiomyopathy had the poorest unadjusted VT-free survival, at 47% (p < 0.01). After adjusting for comorbidities, including age, heart failure severity, ejection fraction, prior ablation, and antiarrhythmic medication use, myocarditis, ARVC, and DICM demonstrated similar outcomes, whereas hypertrophic cardiomyopathy, valvular cardiomyopathy, and sarcoidosis had the highest risk of VT recurrence.ConclusionsCatheter ablation of VT in NICM is effective. Etiology of NICM is a significant predictor of outcomes, with ARVC, myocarditis, and DICM having similar but superior outcomes to hypertrophic cardiomyopathy, valvular cardiomyopathy, and sarcoidosis, after adjusting for potential covariates.
Project description:Radiofrequency catheter ablation has become an established treatment for ventricular tachycardia. The exponential increase in procedures has provided further insights into mechanisms causing arrhythmias and identification of ablation targets with the development of new mapping strategies. Since the definition of criteria to identify myocardial dense scar, borderzone and normal myocardium, and the description of isolated late potentials, local abnormal ventricular activity and decrementing evoked potential mapping, substrate-guided ablation has progressively become the method of choice to guide procedures. Accordingly, a wide range of ablation strategies have been developed from scar homogenization to scar dechanneling or core isolation using increasingly complex and precise tools such as multipolar or omnipolar mapping catheters. Despite these advances long-term success rates for VT ablation have remained static and lower in nonischemic than ischemic heart disease because of the more patchy distribution of myocardial scar. Ablation aims to deliver an irreversible loss of cellular excitability by myocardial heating to a temperatures exceeding 50°C. Many indicators of ablation efficacy have been developed such as contact force, impedance drop, force-time integral and ablation index, mostly validated in atrial fibrillation ablation. In ventricular procedures there is limited data and ablation lesion parameters have been scarcely investigated. Since VT arrhythmia recurrence can be related to inadequate RF lesion formation, it seems reasonable to establish robust markers of ablation efficacy.
Project description:Radiofrequency (RF) ablation with irrigated tip catheters decreases the likelihood of thrombus and char formation and enables the creation of larger lesions. Due to the potential dramatic consequences, the prevention of thromboembolic events is of particular importance for left-sided procedures. Although acute success rates of ventricular tachycardia (VT) ablation are satisfactory, recurrence rate is high. Apart from the progress of the underlying disease, reconduction and the lack of effective transmural lesions play a major role for VT recurrences. This paper reviews principles of lesion formation with radiofrequency and the effect of tip irrigation as well as recent advances in new technology. Potential areas of further development of catheter technology might be the improvement of mapping by better substrate definition and resolution, the introduction of bipolar and multipolar ablation techniques into clinical routine, and the use of alternative sources of energy.